Study on the Flow Characteristics and Energy Dissipation of Side Inlet/Outlet Structures

As a critical hydraulic component of pumped storage power stations, the side inlet/outlet directly affects unit efficiency, flow stability, and system safety. This study investigates the side inlet/outlet of a pumped storage power station using three-dimensional numerical simulations, focusing on the influence of the diffuser length L on hydraulic performance, and further analyzes the underlying mechanisms of energy loss based on entropy production theory. The results indicate that, with increasing diffuser length L, the flow rates in individual channels gradually deviate from the design values, leading to an aggravated imbalance in flow distribution. In contrast, the velocity non-uniformity coefficient CV at the trash rack decreases, accompanied by a pronounced attenuation of recirculation and local flow separation, resulting in a more uniform and stable flow field. Moreover, increasing L improves the streamwise velocity uniformity within each channel, while the extent and intensity of the top recirculation zone are reduced, suppressing local flow separation. Quantitative analysis shows that when L increases from 65 m to 85 m, the total turbulent dissipation entropy production rate in the diffuser section increases linearly from 2732.32 W/K to 2842.32 W/K, whereas the direct dissipation entropy production rate increases from 0.41 W/K to 0.59 W/K. This indicates that turbulent dissipation entropy production plays a dominant role in the overall energy loss. Shorter diffusers tend to induce high-intensity local dissipation, whereas longer diffusers reduce local peak dissipation but increase the overall entropy production within the diffuser, reflecting a trade-off between local optimization and global energy loss. This study reveals the sensitivity and governing effects of diffuser length on the hydraulic characteristics of side inlet/outlets, providing a reference for geometry optimization and engineering design of similar hydraulic components.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-03-13
DOI
https://doi.org/10.3390/w18060678
Primary Topic
Hydraulic flow and structures
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Flow Characteristics and Energy Dissipation of Side Inlet/Outlet Structures

Wangru Wei, Qiang Long, Mingjiang Liu, Jun Deng et al.
Water
Hydraulic flow and structures
article

Study on the Flow Characteristics and Energy Dissipation of Side Inlet/Outlet Structures

Wangru Wei, Qiang Long, Mingjiang Liu, Jun Deng, Hai-Yan Lv
article en

Abstract

As a critical hydraulic component of pumped storage power stations, the side inlet/outlet directly affects unit efficiency, flow stability, and system safety. This study investigates the side inlet/outlet of a pumped storage power station using three-dimensional numerical simulations, focusing on the influence of the diffuser length L on hydraulic performance, and further analyzes the underlying mechanisms of energy loss based on entropy production theory. The results indicate that, with increasing diffuser length L, the flow rates in individual channels gradually deviate from the design values, leading to an aggravated imbalance in flow distribution. In contrast, the velocity non-uniformity coefficient CV at the trash rack decreases, accompanied by a pronounced attenuation of recirculation and local flow separation, resulting in a more uniform and stable flow field. Moreover, increasing L improves the streamwise velocity uniformity within each channel, while the extent and intensity of the top recirculation zone are reduced, suppressing local flow separation. Quantitative analysis shows that when L increases from 65 m to 85 m, the total turbulent dissipation entropy production rate in the diffuser section increases linearly from 2732.32 W/K to 2842.32 W/K, whereas the direct dissipation entropy production rate increases from 0.41 W/K to 0.59 W/K. This indicates that turbulent dissipation entropy production plays a dominant role in the overall energy loss. Shorter diffusers tend to induce high-intensity local dissipation, whereas longer diffusers reduce local peak dissipation but increase the overall entropy production within the diffuser, reflecting a trade-off between local optimization and global energy loss. This study reveals the sensitivity and governing effects of diffuser length on the hydraulic characteristics of side inlet/outlets, providing a reference for geometry optimization and engineering design of similar hydraulic components.

WaterVol. 18(6)
Sichuan University (CN), PowerChina (China) (CN), State Key Laboratory of Hydraulics and Mountain River Engineering
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 22%
Hydraulic flow and structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.