Characterization of a photon counting micro computed tomography laboratory setup

The imaging capabilities of an in-house X-ray setup for micro computed tomography, consisting of a photon-counting detector and a liquid target source, are reported here. The effect of the finite X-ray source spot size on the image resolution is measured using the slanted edge method at different sample-to-detector distances, and the energy response of the detector is probed using clinically relevant contrast agents. The results show that the spatial resolution is limited to $12$ $\mu$m at large sample magnification. The energy resolution of the detector could not be estimated based on the present experiment and data analysis. The method used to measure the spatial resolution could be useful for research groups wanting to characterize similar X-ray setups.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-09-26
DOI
https://doi.org/10.1093/rpd/ncaf120
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of a photon counting micro computed tomography laboratory setup

Robin Krüger, Marie‐Louise Aurumskjöld, Martin Bech, Niccolò Peruzzi et al.
Radiation Protection Dosimetry
Advanced X-ray and CT Imaging
article

Characterization of a photon counting micro computed tomography laboratory setup

Robin Krüger, Marie‐Louise Aurumskjöld, Martin Bech, Niccolò Peruzzi, My Celander
article en

Abstract

The imaging capabilities of an in-house X-ray setup for micro computed tomography, consisting of a photon-counting detector and a liquid target source, are reported here. The effect of the finite X-ray source spot size on the image resolution is measured using the slanted edge method at different sample-to-detector distances, and the energy response of the detector is probed using clinically relevant contrast agents. The results show that the spatial resolution is limited to $12$ $\mu$m at large sample magnification. The energy resolution of the detector could not be estimated based on the present experiment and data analysis. The method used to measure the spatial resolution could be useful for research groups wanting to characterize similar X-ray setups.

Radiation Protection DosimetryVol. 202(3–4)
Malmö University (SE), Lund University (SE), Skåne University Hospital (SE)
Affordable and clean energy
Openalex Percentile: Top 37%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of a photon counting micro computed tomography laboratory setup — Robin Krüger, Marie‐Louise Aurumskjöld, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS