A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications

Reliable terahertz radiometer receiver systems demand detectors that combine high sensitivity with structural robustness. This paper presents the design, fabrication, and characterization of a 380 GHz zero-bias detector based on an ACST Schottky diode. The detector uses a high-impedance grounding topology to reduce parasitic resonances and enhance output stability. A compact U-shaped waveguide transition is adopted to realize an inline port configuration. This configuration simplifies system integration. Measurements demonstrate a peak voltage responsivity of 2318 V/W and a linearity of 0.9996 at 380 GHz, validating the effectiveness of the proposed design. This work establishes a practical design approach for zero-bias terahertz detectors and supports future high-frequency radiometer and sensing applications.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-03-13
DOI
https://doi.org/10.3390/mi17030352
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications

Yongsheng Deng, Dehai Zhang, Huilin Tang
Micromachines
Superconducting and THz Device Technology
article

A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications

Yongsheng Deng, Dehai Zhang, Huilin Tang
article en

Abstract

Reliable terahertz radiometer receiver systems demand detectors that combine high sensitivity with structural robustness. This paper presents the design, fabrication, and characterization of a 380 GHz zero-bias detector based on an ACST Schottky diode. The detector uses a high-impedance grounding topology to reduce parasitic resonances and enhance output stability. A compact U-shaped waveguide transition is adopted to realize an inline port configuration. This configuration simplifies system integration. Measurements demonstrate a peak voltage responsivity of 2318 V/W and a linearity of 0.9996 at 380 GHz, validating the effectiveness of the proposed design. This work establishes a practical design approach for zero-bias terahertz detectors and supports future high-frequency radiometer and sensing applications.

MicromachinesVol. 17(3)
Chinese Academy of Sciences (CN), National Space Science Center (CN), University of Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 23%
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.