Biomechanical evaluation of mesh-based mandibular reconstruction plates and their implication for temporomandibular joint prosthesis

• The present work compares mesh-based and conventional plates for mandible and TMJ reconstruction. • Experimental validation confirms FEA predictions within 7% stiffness deviation • The mesh-based Ti-6Al-4V plates improved load distribution over conventional solid plates. • Integration of mesh plate and TMJ prosthesis lowered fossa stress by up to 50%. Mandibular reconstruction involving the temporomandibular joint (TMJ) presents clinical challenges due to the need for both structural integrity and joint function. This study developed and biomechanically evaluated patient-specific mandibular reconstruction plates integrated with TMJ prostheses, focusing on mesh-based designs as an alternative to the conventional solid plate. The samples studied in this work included the conventional plate (CON-plate) and the mesh-based variants with relative densities (RD) from 0.2 to 1.0, fabricated using metal additive manufacturing. Finite element analysis (FEA) was validated with experimental compression tests, showing strong agreement in resulting stiffness, where both results differed by less than 7%. Under simulated masticatory loading, mesh-based plates demonstrated more uniform stress distribution, reducing peak stresses in both plates and screws by approximately 60%. In addition, an effective stress parameter was introduced to indicate mechanical efficiency relative to mass, demonstrating that the mesh-based plates achieve an improved stress–mass trade-off than the conventional design. Additionally, tribological testing showed that post-processing of Ti-6Al-4V pins reduced UHMWPE wear rate from 1.44 × 10 -4 mm 3 /Nm to 1.21 × 10 -4 mm 3 /Nm, highlighting the importance of surface finish. Integration of mesh-based plates also lowered von Mises stress and contact pressure in UHMWPE fossa components, indicating reduced wear potential. Overall, the mesh-based reconstruction plates present a promising strategy to enhance load transfer, minimize implant wear, and improve long-term outcomes for both mandibular reconstruction and TMJ prosthesis.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-03-14
DOI
https://doi.org/10.1016/j.rineng.2026.110026
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of mesh-based mandibular reconstruction plates and their implication for temporomandibular joint prosthesis

Vikram Ahuja, Vorapat Trachoo, Patcharapit Promoppatum, Viritpon Srimaneepong et al.
Results in Engineering
Temporomandibular Joint Disorders
article

Biomechanical evaluation of mesh-based mandibular reconstruction plates and their implication for temporomandibular joint prosthesis

Vikram Ahuja, Vorapat Trachoo, Patcharapit Promoppatum, Viritpon Srimaneepong, Pukanant Vilai, Pattraporn Sngobsrijintana, Wanrudee Chankaew, Suwichaya Ampaites
article en

Abstract

• The present work compares mesh-based and conventional plates for mandible and TMJ reconstruction. • Experimental validation confirms FEA predictions within 7% stiffness deviation • The mesh-based Ti-6Al-4V plates improved load distribution over conventional solid plates. • Integration of mesh plate and TMJ prosthesis lowered fossa stress by up to 50%. Mandibular reconstruction involving the temporomandibular joint (TMJ) presents clinical challenges due to the need for both structural integrity and joint function. This study developed and biomechanically evaluated patient-specific mandibular reconstruction plates integrated with TMJ prostheses, focusing on mesh-based designs as an alternative to the conventional solid plate. The samples studied in this work included the conventional plate (CON-plate) and the mesh-based variants with relative densities (RD) from 0.2 to 1.0, fabricated using metal additive manufacturing. Finite element analysis (FEA) was validated with experimental compression tests, showing strong agreement in resulting stiffness, where both results differed by less than 7%. Under simulated masticatory loading, mesh-based plates demonstrated more uniform stress distribution, reducing peak stresses in both plates and screws by approximately 60%. In addition, an effective stress parameter was introduced to indicate mechanical efficiency relative to mass, demonstrating that the mesh-based plates achieve an improved stress–mass trade-off than the conventional design. Additionally, tribological testing showed that post-processing of Ti-6Al-4V pins reduced UHMWPE wear rate from 1.44 × 10 -4 mm 3 /Nm to 1.21 × 10 -4 mm 3 /Nm, highlighting the importance of surface finish. Integration of mesh-based plates also lowered von Mises stress and contact pressure in UHMWPE fossa components, indicating reduced wear potential. Overall, the mesh-based reconstruction plates present a promising strategy to enhance load transfer, minimize implant wear, and improve long-term outcomes for both mandibular reconstruction and TMJ prosthesis.

Results in EngineeringVol. 30
PTT Public Company Limited (Thailand) (TH), Chulalongkorn University (TH), Indiana University Bloomington (US), King Mongkut's University of Technology Thonburi (TH), Srinakharinwirot University (TH)
Zero hunger
Openalex Percentile: Top 21%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.