Clinical experience of automated QC for homogeneous image analysis

DOSESTAT-QC® is a stand-alone automated quality control (QC) system used for daily quality assurance of X-ray equipment in Jönköping Region, Sweden. The software has been implemented for all mammography systems and interventional systems in the region. One of the image analysis included in the DOSESTAT-QC® software is performed in homogenous images and focuses on the standard deviations in mean pixel value (MV) and signal-to-noise ratio (SNR) in the images. Initially, the analyses were performed in 1 cm2 regions of interest (ROIs) and the obtained values in each ROI were compared to the corresponding values for the entire image. While MV remained relatively stable over time, fluctuations in SNR together with imprecise localization of pixel errors, especially in the automatic exposure control (AEC) area, highlighted limitations. In this paper, an improved method for image evaluation is presented, which enables precise SNR baseline settings and clear visualization of deviations and dead pixels. Additionally, the adaption and clinical implementation of DOSESTAT-QC® to conventional X-ray systems in the region are described.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-12-23
DOI
https://doi.org/10.1093/rpd/ncaf194
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical experience of automated QC for homogeneous image analysis

Angelica Svalkvist, Tanny Visanuyanont, Emanuel Hillberg, Tomas Moberg
Radiation Protection Dosimetry
Digital Radiography and Breast Imaging
article

Clinical experience of automated QC for homogeneous image analysis

Angelica Svalkvist, Tanny Visanuyanont, Emanuel Hillberg, Tomas Moberg
article en

Abstract

DOSESTAT-QC® is a stand-alone automated quality control (QC) system used for daily quality assurance of X-ray equipment in Jönköping Region, Sweden. The software has been implemented for all mammography systems and interventional systems in the region. One of the image analysis included in the DOSESTAT-QC® software is performed in homogenous images and focuses on the standard deviations in mean pixel value (MV) and signal-to-noise ratio (SNR) in the images. Initially, the analyses were performed in 1 cm2 regions of interest (ROIs) and the obtained values in each ROI were compared to the corresponding values for the entire image. While MV remained relatively stable over time, fluctuations in SNR together with imprecise localization of pixel errors, especially in the automatic exposure control (AEC) area, highlighted limitations. In this paper, an improved method for image evaluation is presented, which enables precise SNR baseline settings and clear visualization of deviations and dead pixels. Additionally, the adaption and clinical implementation of DOSESTAT-QC® to conventional X-ray systems in the region are described.

Radiation Protection DosimetryVol. 202(3–4)
Uppsala University (SE), Sahlgrenska University Hospital (SE), Region Jönköpings län (SE), Ryhov Hospital Jönköping (SE), University of Gothenburg (SE)
Openalex Percentile: Top 23%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical experience of automated QC for homogeneous image analysis — Angelica Svalkvist, Tanny Visanuyanont, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS