Utilization of Alanine Dosimetry for 10 MV Photon Beam Dose Evaluation

Radiation therapy is a crucial treatment method that delivers a high dose of radiation to localized areas. Therefore, ensuring the accuracy of the radiation dose from the radiation generator is essential. Alanine dosimetry offers the advantage of being equivalent to water and tissue and is thus a valuable tool for estimating radiation doses in the human body. In this study, we aimed to assess the feasibility of utilizing electron paramagnetic resonance (EPR)/alanine dosimetry for quality control of medical linear accelerators (LINACs). The EPR signal and slope of the dose-response curve were compared with the number of alanine dosimeters per dose using a 10 MV linear accelerator, and the measurement uncertainty was evaluated. The signal increased by approximately 0.03 per 1 Gy per count, in conjunction with the slope of the dose-response curve. The measurement uncertainty, estimated based on the synthesis of eight numerical factors of the uncertainty propagation law, was approximately 2.49-4.19% (k = 1). The findings of this study suggest that the EPR/alanine dosimetry system can be reliably applied for quality control of 10 MV photon beams under the investigated experimental conditions.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2026-03-13
DOI
https://doi.org/10.3390/molecules31060971
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilization of Alanine Dosimetry for 10 MV Photon Beam Dose Evaluation

Wol Soon JO, Jeung Kee Kim, Doyoung Jung, Ji-Eun Lee et al.
Molecules
Radiation Effects and Dosimetry
article

Utilization of Alanine Dosimetry for 10 MV Photon Beam Dose Evaluation

Wol Soon JO, Jeung Kee Kim, Doyoung Jung, Ji-Eun Lee, Yong-Uk Kye, HyoJin Kim, Yeong-Rok Kang, Jeong-Hwa Baek, Hee Jin Jang
article en

Abstract

Radiation therapy is a crucial treatment method that delivers a high dose of radiation to localized areas. Therefore, ensuring the accuracy of the radiation dose from the radiation generator is essential. Alanine dosimetry offers the advantage of being equivalent to water and tissue and is thus a valuable tool for estimating radiation doses in the human body. In this study, we aimed to assess the feasibility of utilizing electron paramagnetic resonance (EPR)/alanine dosimetry for quality control of medical linear accelerators (LINACs). The EPR signal and slope of the dose-response curve were compared with the number of alanine dosimeters per dose using a 10 MV linear accelerator, and the measurement uncertainty was evaluated. The signal increased by approximately 0.03 per 1 Gy per count, in conjunction with the slope of the dose-response curve. The measurement uncertainty, estimated based on the synthesis of eight numerical factors of the uncertainty propagation law, was approximately 2.49-4.19% (k = 1). The findings of this study suggest that the EPR/alanine dosimetry system can be reliably applied for quality control of 10 MV photon beams under the investigated experimental conditions.

MoleculesVol. 31(6)
Dongnam Institute of Radiological & Medical Sciences (KR)
Ministry of Science and ICT, South Korea
Clean water and sanitation
Openalex Percentile: Top 22%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.