Electro-osmotic control of X80 steel corrosion under HVDC interference

X80 pipeline steel in natural clay soil exhibits a pronounced non-monotonic corrosion kinetic peak under HVDC interference—a phenomenon that deviates significantly from classical electrochemical predictions and challenges existing cathodic protection (CP) design standards. The maximum corrosion rate occurs at 200 V with soil moisture decreasing from 13 wt% to 8 wt% within 8 h. Through decoupled electrochemical and electro-osmotic migration experiments ( n ≥ 3 replicates), we identified electro-osmotic dehydration (EOD) as the dominant mechanism. As water progressively migrates away from the anode/electrolyte interface, soil resistivity increases dramatically by 95%, fundamentally altering electrochemical kinetics. This moisture depletion triggers a critical transition of the rate-determining step from charge-transfer control to ohmic resistance control, explaining why intermediate voltages (150–250 V) generate unexpectedly high corrosion rates despite lower current densities. A coupled Nernst–Planck–Darcy model with saturation-dependent resistivity quantitatively reproduces the non-monotonic trend (prediction error < 7%) and moisture redistribution (error < 4%). The model reveals that corrosion risk concentrates within a specific voltage window under variable soil moisture conditions. These findings establish a multiphysics framework for understanding material degradation in complex electromagnetic environments and provide critical quantitative guidance for pipeline safety assessment in HVDC-affected zones. • Non-monotonic corrosion kinetics of X80 steel are identified under HVDC. • Corrosion rate peaks at 200 V due to electro-osmotic dehydration of soil. • Anodic moisture loss shifts the control from activation to ohmic resistance. • A Nernst-Planck-Darcy model predicts the coupled transport processes. • Kinetic anomalies are quantified through saturation-dependent resistivity.

Authors

Institutions

Publication Details

Journal
Electrochemistry Communications
Published
2026-03-13
DOI
https://doi.org/10.1016/j.elecom.2026.108148
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electro-osmotic control of X80 steel corrosion under HVDC interference

Xi Yang, Gengsheng Chen, Z. Huang, Ziru Chang et al.
Electrochemistry Communications
Hydrogen embrittlement and corrosion behaviors in metals
article

Electro-osmotic control of X80 steel corrosion under HVDC interference

Xi Yang, Gengsheng Chen, Z. Huang, Ziru Chang, Dong Zhang, Yu Ding, Zitao Jiang, Yunan Zhang
article en

Abstract

X80 pipeline steel in natural clay soil exhibits a pronounced non-monotonic corrosion kinetic peak under HVDC interference—a phenomenon that deviates significantly from classical electrochemical predictions and challenges existing cathodic protection (CP) design standards. The maximum corrosion rate occurs at 200 V with soil moisture decreasing from 13 wt% to 8 wt% within 8 h. Through decoupled electrochemical and electro-osmotic migration experiments ( n ≥ 3 replicates), we identified electro-osmotic dehydration (EOD) as the dominant mechanism. As water progressively migrates away from the anode/electrolyte interface, soil resistivity increases dramatically by 95%, fundamentally altering electrochemical kinetics. This moisture depletion triggers a critical transition of the rate-determining step from charge-transfer control to ohmic resistance control, explaining why intermediate voltages (150–250 V) generate unexpectedly high corrosion rates despite lower current densities. A coupled Nernst–Planck–Darcy model with saturation-dependent resistivity quantitatively reproduces the non-monotonic trend (prediction error < 7%) and moisture redistribution (error < 4%). The model reveals that corrosion risk concentrates within a specific voltage window under variable soil moisture conditions. These findings establish a multiphysics framework for understanding material degradation in complex electromagnetic environments and provide critical quantitative guidance for pipeline safety assessment in HVDC-affected zones. • Non-monotonic corrosion kinetics of X80 steel are identified under HVDC. • Corrosion rate peaks at 200 V due to electro-osmotic dehydration of soil. • Anodic moisture loss shifts the control from activation to ohmic resistance. • A Nernst-Planck-Darcy model predicts the coupled transport processes. • Kinetic anomalies are quantified through saturation-dependent resistivity.

Electrochemistry CommunicationsVol. 186
China University of Petroleum, Beijing (CN), University of Science and Technology Beijing (CN)
Life in Land
Openalex Percentile: Top 23%
Hydrogen embrittlement and corrosion behaviors in metals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.