Adaptive, Privacy-Preserving Small Language Models for Multi-Task Clinical Assistance

The purpose of this study is to evaluate whether a single, fine-tuned SLM can match or exceed the performance of LLMs across diverse clinical tasks, enabling hospitals to build tailored, privacy-preserving, efficient, and deployable language models that do not require managing multiple task-specific systems. We used SLMs of varying sizes and applied low-rank adaptation (LoRA) for fine-tuning across three clinical tasks: (1) medical report labeling, (2) DICOM series description harmonization, and (3) impression generation from findings. These tasks were constructed using two datasets: the public Open-i Indiana University Chest X-ray Dataset and an in-house brain MRI DICOM metadata dataset. We compared single-task SLMs, a multi-task SLM (representing our proposed configuration), and GPT-4o using zero-shot and few-shot prompting. We found OPT-350 m to be the optimal SLM. In medical report labeling, the multi-task SLM achieved an F1 score of 0.894 compared to additional prompt-engineered GPT-4o's 0.728. In DICOM series description harmonization, the multi-task achieved an accuracy of 0.975 compared to additional prompt-engineered GPT-4o's 0.878. In impression generation from findings, the multi-task SLM achieved an average Likert scale score of 4.39 ± 1.00, compared to GPT-4o's 3.65 ± 1.00 (p = 0.0008). This study demonstrates that a single fine-tuned SLM can serve as a general-purpose clinical assistant, offering performance on par with or better than larger models. With lower resource requirements, greater customizability, privacy protection, and strong task generalization, fine-tuning one SLM to support multiple clinical tasks meets the practical demands of clinical AI deployment in both high-resource and resource-limited healthcare settings.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-03-13
DOI
https://doi.org/10.1007/s10278-026-01912-4
Primary Topic
Privacy-Preserving Technologies in Data
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive, Privacy-Preserving Small Language Models for Multi-Task Clinical Assistance

Jay J. Pillai, Alireza Akhbardeh, Guangyao Zheng, Vladimir Braverman et al.
Journal of Imaging Informatics in Medicine
Privacy-Preserving Technologies in Data
article

Adaptive, Privacy-Preserving Small Language Models for Multi-Task Clinical Assistance

Jay J. Pillai, Alireza Akhbardeh, Guangyao Zheng, Vladimir Braverman, Vishwa S. Parekh, Peter Kamel, Michael A. Jacobs
article en

Abstract

The purpose of this study is to evaluate whether a single, fine-tuned SLM can match or exceed the performance of LLMs across diverse clinical tasks, enabling hospitals to build tailored, privacy-preserving, efficient, and deployable language models that do not require managing multiple task-specific systems. We used SLMs of varying sizes and applied low-rank adaptation (LoRA) for fine-tuning across three clinical tasks: (1) medical report labeling, (2) DICOM series description harmonization, and (3) impression generation from findings. These tasks were constructed using two datasets: the public Open-i Indiana University Chest X-ray Dataset and an in-house brain MRI DICOM metadata dataset. We compared single-task SLMs, a multi-task SLM (representing our proposed configuration), and GPT-4o using zero-shot and few-shot prompting. We found OPT-350 m to be the optimal SLM. In medical report labeling, the multi-task SLM achieved an F1 score of 0.894 compared to additional prompt-engineered GPT-4o's 0.728. In DICOM series description harmonization, the multi-task achieved an accuracy of 0.975 compared to additional prompt-engineered GPT-4o's 0.878. In impression generation from findings, the multi-task SLM achieved an average Likert scale score of 4.39 ± 1.00, compared to GPT-4o's 3.65 ± 1.00 (p = 0.0008). This study demonstrates that a single fine-tuned SLM can serve as a general-purpose clinical assistant, offering performance on par with or better than larger models. With lower resource requirements, greater customizability, privacy protection, and strong task generalization, fine-tuning one SLM to support multiple clinical tasks meets the practical demands of clinical AI deployment in both high-resource and resource-limited healthcare settings.

Journal of Imaging Informatics in Medicine
The University of Texas MD Anderson Cancer Center (US), Johns Hopkins University (US), Johns Hopkins Medicine (US), Sidney Kimmel Cancer Center (US), Mayo Clinic in Arizona (US), The University of Texas Health Science Center (US), Sidney Kimmel Comprehensive Cancer Center (US), Rice University (US)
Openalex Percentile: Top 27%
Privacy-Preserving Technologies in Data
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.