Enhancing the Detection of Long-Chain Aldehydes by Peptide-Based Biosensors Through Counter-Ion Exchange

Long-chain aldehydes, particularly nonanal, are recognized as potential volatile biomarkers of lung cancer in exhaled breath. This study investigates the influence of peptide counter-ions on the performance of QCM-based biosensors using two odorant-binding protein-derived peptides (OBPP4 and OBPP4 GSGSGS) for the selective gas-phase detection of these aldehydes. Exchanging the counter-ion from trifluoroacetate to chloride improves biosensor sensitivity and lowers the limit of detection within the set of biosensors investigated in this study. The OBPP4 GSGSGS with chloride exhibited the highest sensitivity to nonanal (0.153 Hz/ppm) and the lowest LOD (9.8 ppm), with excellent selectivity over other groups of volatiles. The novelty of this work lies in demonstrating, for the first time, that simple counter-ion exchange in synthetic peptides can significantly enhance the gas-phase binding of volatile aldehydes, classified as lung cancer biomarkers, without altering the peptide sequence, offering a straightforward and effective optimization strategy for peptide-based piezoelectric biosensors.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-03-13
DOI
https://doi.org/10.3390/bios16030162
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Detection of Long-Chain Aldehydes by Peptide-Based Biosensors Through Counter-Ion Exchange

Jacek Gębicki, Elisabete P. Fernandes, Tomasz Wasilewski, Marek Wojciechowski et al.
Biosensors
Advanced Chemical Sensor Technologies
article

Enhancing the Detection of Long-Chain Aldehydes by Peptide-Based Biosensors Through Counter-Ion Exchange

Jacek Gębicki, Elisabete P. Fernandes, Tomasz Wasilewski, Marek Wojciechowski, Damian Neubauer, Bartosz Szulczyński, Wojciech Kamysz, Rafał Kiejzik
article en

Abstract

Long-chain aldehydes, particularly nonanal, are recognized as potential volatile biomarkers of lung cancer in exhaled breath. This study investigates the influence of peptide counter-ions on the performance of QCM-based biosensors using two odorant-binding protein-derived peptides (OBPP4 and OBPP4 GSGSGS) for the selective gas-phase detection of these aldehydes. Exchanging the counter-ion from trifluoroacetate to chloride improves biosensor sensitivity and lowers the limit of detection within the set of biosensors investigated in this study. The OBPP4 GSGSGS with chloride exhibited the highest sensitivity to nonanal (0.153 Hz/ppm) and the lowest LOD (9.8 ppm), with excellent selectivity over other groups of volatiles. The novelty of this work lies in demonstrating, for the first time, that simple counter-ion exchange in synthetic peptides can significantly enhance the gas-phase binding of volatile aldehydes, classified as lung cancer biomarkers, without altering the peptide sequence, offering a straightforward and effective optimization strategy for peptide-based piezoelectric biosensors.

BiosensorsVol. 16(3)
Gdańsk University of Technology (PL), International Iberian Nanotechnology Laboratory (PT), Gdańsk Medical University (PL)
Openalex Percentile: Top 23%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.