Optimizing extremity dosimetry: an investigation of thermoluminescence dosemeter ring orientation when handling radioactive sources

Accurate extremity dosimetry is essential in nuclear medicine due to finger exposure being one of the major radiation protection concerns. Instinctive ring wearing habits, such as facing decorative elements outwards or 'diamond-up', frequently leads to incorrectly orientated thermoluminescence dosemeter (TLD) ring placement. This study investigated how the orientation of TLD rings can affect recorded extremity dose when handling 99mTc. A two-part method was undertaken involving a physical experiment using a constructed finger phantom followed by a Geant4 Monte Carlo simulation to validate the findings. The results highlighted that doses were significantly reduced by a ratio of 19:1 (-95%) when TLD dosemeter rings were orientated outward when compared to inward, primarily due to the additional attenuation introduced by the finger. Greater awareness on the influence of ring orientation is essential for improving the accuracy of extremity dosimetry, addressing a simple yet often overlooked aspect of radiation protection.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-11-27
DOI
https://doi.org/10.1093/rpd/ncaf155
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing extremity dosimetry: an investigation of thermoluminescence dosemeter ring orientation when handling radioactive sources

Scott Grieve
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Optimizing extremity dosimetry: an investigation of thermoluminescence dosemeter ring orientation when handling radioactive sources

Scott Grieve
article en

Abstract

Accurate extremity dosimetry is essential in nuclear medicine due to finger exposure being one of the major radiation protection concerns. Instinctive ring wearing habits, such as facing decorative elements outwards or 'diamond-up', frequently leads to incorrectly orientated thermoluminescence dosemeter (TLD) ring placement. This study investigated how the orientation of TLD rings can affect recorded extremity dose when handling 99mTc. A two-part method was undertaken involving a physical experiment using a constructed finger phantom followed by a Geant4 Monte Carlo simulation to validate the findings. The results highlighted that doses were significantly reduced by a ratio of 19:1 (-95%) when TLD dosemeter rings were orientated outward when compared to inward, primarily due to the additional attenuation introduced by the finger. Greater awareness on the influence of ring orientation is essential for improving the accuracy of extremity dosimetry, addressing a simple yet often overlooked aspect of radiation protection.

Radiation Protection DosimetryVol. 202(3–4)
Integrated Radiological Services (United Kingdom) (GB)
Openalex Percentile: Top 25%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.