High-temporal resolution metabolic connectivity resolved by component-based noise correction

Recent advances in functional PET (fPET) enable modeling of metabolic processes with second-level temporal resolution, opening applications such as imaging molecular connectivity comparable to fMRI. However, high-temporal fPET is more noise-sensitive, making meaningful signal extraction challenging. We developed a component-based preprocessing method adapted from fMRI, which models structured noise with tissue-specific regressors and removes low-frequency uptake trends (CompCor). This approach was applied to 20 high-temporal [<sup>18</sup>F]FDG-fPET scans from a long-axial PET/CT system (1 s frames) and 16 scans from a PET/MR scanner (3 s frames). Filtering methods were compared across frequency bands, and their effects on metabolic connectivity (M-MC) assessed. Connectivity was strongly influenced by filter strategy and scanner type. CompCor produced more consistent, structured networks than standard bandpass filters. Intermediate frequency bands (0.01-0.1 Hz) gave the most reliable connectivity across PET/CT and PET/MR (<i>r</i> = 0.89), while high-sensitivity PET/CT also revealed structured patterns at 0.1-0.2 Hz. Compared to fMRI, fPET networks appeared more spatially cohesive but less differentiated. In sum, high-temporal [<sup>18</sup>F]FDG-fPET enables high within-scan reliability estimation of resting-state M-MC when paired with appropriate denoising, opening a new avenue in molecular imaging. Scanner characteristics and preprocessing critically affect signal quality, while our physiologically informed pipeline improves comparability across systems and studies.

Authors

Institutions

Publication Details

Journal
Journal of Cerebral Blood Flow & Metabolism
Published
2026-03-13
DOI
https://doi.org/10.1177/0271678x261431043
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-temporal resolution metabolic connectivity resolved by component-based noise correction

Christian Milz, L. Silberbauer, Murray Bruce Reed, Pia Falb et al.
Journal of Cerebral Blood Flow & Metabolism
Medical Imaging Techniques and Applications
article

High-temporal resolution metabolic connectivity resolved by component-based noise correction

Christian Milz, L. Silberbauer, Murray Bruce Reed, Pia Falb, Alexandra Mayerweg, Gabriel Schlosser, Samantha Graf, Benjamin Eggerstorfer, Godber M Godbersen, Sazan Rasul, Sebastian Klug, A. Hahn, Elisa Briem, Rupert Lanzenberger, Lukas Nics, Marcus Hacker, Matej Murgaš
article en

Abstract

Recent advances in functional PET (fPET) enable modeling of metabolic processes with second-level temporal resolution, opening applications such as imaging molecular connectivity comparable to fMRI. However, high-temporal fPET is more noise-sensitive, making meaningful signal extraction challenging. We developed a component-based preprocessing method adapted from fMRI, which models structured noise with tissue-specific regressors and removes low-frequency uptake trends (CompCor). This approach was applied to 20 high-temporal [<sup>18</sup>F]FDG-fPET scans from a long-axial PET/CT system (1 s frames) and 16 scans from a PET/MR scanner (3 s frames). Filtering methods were compared across frequency bands, and their effects on metabolic connectivity (M-MC) assessed. Connectivity was strongly influenced by filter strategy and scanner type. CompCor produced more consistent, structured networks than standard bandpass filters. Intermediate frequency bands (0.01-0.1 Hz) gave the most reliable connectivity across PET/CT and PET/MR (<i>r</i> = 0.89), while high-sensitivity PET/CT also revealed structured patterns at 0.1-0.2 Hz. Compared to fMRI, fPET networks appeared more spatially cohesive but less differentiated. In sum, high-temporal [<sup>18</sup>F]FDG-fPET enables high within-scan reliability estimation of resting-state M-MC when paired with appropriate denoising, opening a new avenue in molecular imaging. Scanner characteristics and preprocessing critically affect signal quality, while our physiologically informed pipeline improves comparability across systems and studies.

Journal of Cerebral Blood Flow & Metabolism
Medical University of Vienna (AT)
Openalex Percentile: Top 24%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.