Integrated assessment of contrast-enhanced TCD and TTE for noninvasive detection of patent foramen ovale under resting and Valsalva conditions

Objective To compare the diagnostic performance of contrast-enhanced transcranial Doppler (c-TCD) and contrast-enhanced transthoracic echocardiography (c-TTE) under resting and Valsalva conditions for detecting patent foramen ovale (PFO), and to evaluate the clinical utility of an integrated diagnostic model combining both modalities. Materials and methods In this retrospective study, a total of 146 patients with suspected PFO underwent both c-TCD and c-TTE at rest and during the Valsalva maneuver. Among them, 40 patients also received contrast-enhanced transesophageal echocardiography (c-TEE), which served as the reference standard. Detection rates, shunt grading, and inter-modality agreement were analyzed. A logistic regression model integrating c-TCD and c-TTE findings was developed and assessed using receiver operating characteristic (ROC) curves and decision curve analysis (DCA). Results The Valsalva maneuver significantly increased the detection rates of right-to-left shunt (c-TCD: from 41.4% to 76.7%; c-TTE: from 45.2% to 80.1%) and the proportion of Grade 3 shunts ( P < 0.0001). At rest, c-TCD detected more high-grade shunts than c-TTE ( P = 0.030), supporting its use as a sensitive initial screening tool. Inter-modality agreement improved markedly during Valsalva (weighted Kappa = 0.782). The combined model achieved 100% sensitivity and negative predictive value in the TEE subgroup, with an area under the ROC curve of 0.97 and no false negatives. DCA confirmed the superior net clinical benefit of the integrated approach across a broad range of decision thresholds. Conclusion Valsalva maneuver significantly enhances the diagnostic yield of both c-TCD and c-TTE. While c-TCD may serve as an effective first-line screening tool, its combination with c-TTE ensures improved diagnostic accuracy and clinical decision-making value. The integrated model demonstrates strong potential for clinical implementation as a noninvasive, efficient strategy to reduce unnecessary c-TEE procedures.

Authors

Institutions

Publication Details

Journal
Frontiers in Neurology
Published
2026-03-13
DOI
https://doi.org/10.3389/fneur.2026.1751043
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated assessment of contrast-enhanced TCD and TTE for noninvasive detection of patent foramen ovale under resting and Valsalva conditions

Hao Chen, Yue Song, Yimin Wu, Junli Wang et al.
Frontiers in Neurology
Cardiovascular and Diving-Related Complications
article

Integrated assessment of contrast-enhanced TCD and TTE for noninvasive detection of patent foramen ovale under resting and Valsalva conditions

Hao Chen, Yue Song, Yimin Wu, Junli Wang, Pingyang Zhang, Hui Yu
article en

Abstract

Objective To compare the diagnostic performance of contrast-enhanced transcranial Doppler (c-TCD) and contrast-enhanced transthoracic echocardiography (c-TTE) under resting and Valsalva conditions for detecting patent foramen ovale (PFO), and to evaluate the clinical utility of an integrated diagnostic model combining both modalities. Materials and methods In this retrospective study, a total of 146 patients with suspected PFO underwent both c-TCD and c-TTE at rest and during the Valsalva maneuver. Among them, 40 patients also received contrast-enhanced transesophageal echocardiography (c-TEE), which served as the reference standard. Detection rates, shunt grading, and inter-modality agreement were analyzed. A logistic regression model integrating c-TCD and c-TTE findings was developed and assessed using receiver operating characteristic (ROC) curves and decision curve analysis (DCA). Results The Valsalva maneuver significantly increased the detection rates of right-to-left shunt (c-TCD: from 41.4% to 76.7%; c-TTE: from 45.2% to 80.1%) and the proportion of Grade 3 shunts ( P < 0.0001). At rest, c-TCD detected more high-grade shunts than c-TTE ( P = 0.030), supporting its use as a sensitive initial screening tool. Inter-modality agreement improved markedly during Valsalva (weighted Kappa = 0.782). The combined model achieved 100% sensitivity and negative predictive value in the TEE subgroup, with an area under the ROC curve of 0.97 and no false negatives. DCA confirmed the superior net clinical benefit of the integrated approach across a broad range of decision thresholds. Conclusion Valsalva maneuver significantly enhances the diagnostic yield of both c-TCD and c-TTE. While c-TCD may serve as an effective first-line screening tool, its combination with c-TTE ensures improved diagnostic accuracy and clinical decision-making value. The integrated model demonstrates strong potential for clinical implementation as a noninvasive, efficient strategy to reduce unnecessary c-TEE procedures.

Frontiers in NeurologyVol. 17
Sun Yat-sen University (CN), Fudan University (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN), Xian Yang Central Hospital (CN), East China Normal University (CN), Nanjing Medical University (CN)
Openalex Percentile: Top 23%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.