A comparison of limited-angle CBCT photon-counting and flat-panel digital mammography in perceived detection and visualization of breast lesions

This investigation aimed to compare perceived lesion detectability and visibility between limited-angle cone-beam computed tomography (CBCT) photon-counting (PC) and flat-panel (FP) mammography at equivalent radiation-dose levels. Projection data were collected by rotating a lesion-containing, humanlike breast phantom and acquiring images at every other degree using both a PC and an FP system, resulting in 5-13 projections over an 8-24° angular range. Feldkamp-Davis-Kress (FDK) and simultaneous iterative reconstruction technique (SIRT) algorithms were used to reconstruct three-dimensional (3D) volumes for each system. A reader study evaluated lesion detectability and visibility in the 3D data. PC-CBCT showed better detectability and visibility of masses compared to FP-CBCT, with 90% sensitivity versus 70% and an area under the visual grading curve (AUCVGC) of 0.66-0.71 (P < .05). FDK image volumes demonstrated improved calcification visibility (P < .05) with PC-CBCT over FP-CBCT; however, for SIRT, calcification visibility was lower (AUCVGC = 0.46). This study emphasizes the need to reassess photon-counting in 3D mammography to improve lesion detection and visibility.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2026-01-22
DOI
https://doi.org/10.1093/rpd/ncaf181
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison of limited-angle CBCT photon-counting and flat-panel digital mammography in perceived detection and visualization of breast lesions

Radu Lesanu, Tony Svahn, Jennifer C. Ast, Ander Biguri
Radiation Protection Dosimetry
Digital Radiography and Breast Imaging
article

A comparison of limited-angle CBCT photon-counting and flat-panel digital mammography in perceived detection and visualization of breast lesions

Radu Lesanu, Tony Svahn, Jennifer C. Ast, Ander Biguri
article en

Abstract

This investigation aimed to compare perceived lesion detectability and visibility between limited-angle cone-beam computed tomography (CBCT) photon-counting (PC) and flat-panel (FP) mammography at equivalent radiation-dose levels. Projection data were collected by rotating a lesion-containing, humanlike breast phantom and acquiring images at every other degree using both a PC and an FP system, resulting in 5-13 projections over an 8-24° angular range. Feldkamp-Davis-Kress (FDK) and simultaneous iterative reconstruction technique (SIRT) algorithms were used to reconstruct three-dimensional (3D) volumes for each system. A reader study evaluated lesion detectability and visibility in the 3D data. PC-CBCT showed better detectability and visibility of masses compared to FP-CBCT, with 90% sensitivity versus 70% and an area under the visual grading curve (AUCVGC) of 0.66-0.71 (P < .05). FDK image volumes demonstrated improved calcification visibility (P < .05) with PC-CBCT over FP-CBCT; however, for SIRT, calcification visibility was lower (AUCVGC = 0.46). This study emphasizes the need to reassess photon-counting in 3D mammography to improve lesion detection and visibility.

Radiation Protection DosimetryVol. 202(3–4)
Uppsala University (SE), University of Cambridge (GB), Gävle Hospital (SE), Centre for Research and Development (ZW)
Openalex Percentile: Top 23%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.