Optimization of radiation protection using diagnostic reference values: current approaches and future directions

Diagnostic reference levels (DRLs) were introduced as a tool to optimize radiation protection in medical imaging. Conditions for dose assessment have evolved significantly. This study explores how effectively the current DRL system functions and whether it requires adjustment. The analysis focuses on the national DRL system in Sweden and includes European projects and guidelines for reference. The variability in typical doses has decreased. National DRL values have been lowered; however, values in nuclear medicine have seen minimal change. These developments present challenges in revising the values. The increased availability of digital data offers both opportunities and challenges. The DRL system may include specific indications, larger patient cohorts, and consideration of patient size. To remain relevant, the DRL system must be updated to reflect changes in clinical practice. The integration of image quality assessment into the DRL framework is one critical area that requires further development.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-08-30
DOI
https://doi.org/10.1093/rpd/ncaf106
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of radiation protection using diagnostic reference values: current approaches and future directions

Anja Almén
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Optimization of radiation protection using diagnostic reference values: current approaches and future directions

Anja Almén
article en

Abstract

Diagnostic reference levels (DRLs) were introduced as a tool to optimize radiation protection in medical imaging. Conditions for dose assessment have evolved significantly. This study explores how effectively the current DRL system functions and whether it requires adjustment. The analysis focuses on the national DRL system in Sweden and includes European projects and guidelines for reference. The variability in typical doses has decreased. National DRL values have been lowered; however, values in nuclear medicine have seen minimal change. These developments present challenges in revising the values. The increased availability of digital data offers both opportunities and challenges. The DRL system may include specific indications, larger patient cohorts, and consideration of patient size. To remain relevant, the DRL system must be updated to reflect changes in clinical practice. The integration of image quality assessment into the DRL framework is one critical area that requires further development.

Radiation Protection DosimetryVol. 202(3–4)
Swedish Radiation Safety Authority (SE), Lund University (SE)
Partnerships for the goals
Openalex Percentile: Top 25%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of radiation protection using diagnostic reference values: current approaches and future directions — Anja Almén · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS