Deep Learning‐Based Inner Ear Subregion Segmentation in 3D T2‐Weighted MRI Using Label‐Preserving Data Augmentation

Inner ear segmentation supports the diagnosis and treatment planning of auditory-related disorders such as Meniere's disease. However, manual annotation of inner ear structures on MR images is both time-consuming and labor-intensive. To address this limitation, we developed a deep learning method that takes T2-weighted MR images as input and segments the inner ear into three subregions: the cochlear basal turn, the cochlear mid-to-apical turn, and the vestibule including the semicircular canals. A total of 74 three-dimensional (3D) T2-weighted MR images were retrospectively collected and divided into 50 training cases and 24 internal test cases. In addition, eight MR images from the publicly available Vestibular-Schwannoma-SEG dataset were used as an independent external test set. Ground-truth segmentations for both the internal and external datasets were manually annotated by an experienced radiologist. A 3D transformer-based deep learning model was trained using these annotated data. To further improve segmentation performance, particularly for the thin and intricate semicircular canals, a label-preserving data augmentation strategy was introduced and compared with a conventional data augmentation approach. Segmentation performance was evaluated using quantitative and qualitative assessments. Quantitative evaluation included the Dice similarity coefficient (DSC), Intersection over union (IoU), and Hausdorff distance (HD). On the internal test set, the proposed method achieved a mean DSC of 0.905 (vs. 0.904), a mean IoU of 0.828 (vs. 0.824), and a mean HD of 2.75 (vs. 3.04) compared with the conventional augmentation approach. On the external dataset, the proposed method demonstrated larger improvements, achieving a mean DSC of 0.919 (vs. 0.847), a mean IoU of 0.852 (vs. 0.738), and a mean HD of 3.92 (vs. 4.45). These results demonstrate that the proposed label-preserving data augmentation method improves the robustness and accuracy of inner ear subregion segmentation, particularly for thin and intricate structures.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-03-13
DOI
https://doi.org/10.1002/nbm.70266
Primary Topic
Vestibular and auditory disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning‐Based Inner Ear Subregion Segmentation in 3D T2‐Weighted MRI Using Label‐Preserving Data Augmentation

Wooseung Kim, Ho‐Joon Lee, Seokhwan Lee, Yoonho Nam et al.
NMR in Biomedicine
Vestibular and auditory disorders
article

Deep Learning‐Based Inner Ear Subregion Segmentation in 3D T2‐Weighted MRI Using Label‐Preserving Data Augmentation

Wooseung Kim, Ho‐Joon Lee, Seokhwan Lee, Yoonho Nam, Yeonah Kang
article en

Abstract

Inner ear segmentation supports the diagnosis and treatment planning of auditory-related disorders such as Meniere's disease. However, manual annotation of inner ear structures on MR images is both time-consuming and labor-intensive. To address this limitation, we developed a deep learning method that takes T2-weighted MR images as input and segments the inner ear into three subregions: the cochlear basal turn, the cochlear mid-to-apical turn, and the vestibule including the semicircular canals. A total of 74 three-dimensional (3D) T2-weighted MR images were retrospectively collected and divided into 50 training cases and 24 internal test cases. In addition, eight MR images from the publicly available Vestibular-Schwannoma-SEG dataset were used as an independent external test set. Ground-truth segmentations for both the internal and external datasets were manually annotated by an experienced radiologist. A 3D transformer-based deep learning model was trained using these annotated data. To further improve segmentation performance, particularly for the thin and intricate semicircular canals, a label-preserving data augmentation strategy was introduced and compared with a conventional data augmentation approach. Segmentation performance was evaluated using quantitative and qualitative assessments. Quantitative evaluation included the Dice similarity coefficient (DSC), Intersection over union (IoU), and Hausdorff distance (HD). On the internal test set, the proposed method achieved a mean DSC of 0.905 (vs. 0.904), a mean IoU of 0.828 (vs. 0.824), and a mean HD of 2.75 (vs. 3.04) compared with the conventional augmentation approach. On the external dataset, the proposed method demonstrated larger improvements, achieving a mean DSC of 0.919 (vs. 0.847), a mean IoU of 0.852 (vs. 0.738), and a mean HD of 3.92 (vs. 4.45). These results demonstrate that the proposed label-preserving data augmentation method improves the robustness and accuracy of inner ear subregion segmentation, particularly for thin and intricate structures.

NMR in BiomedicineVol. 39(4)
Korea Advanced Institute of Science and Technology (KR), Korea Institute of Brain Science (KR), Inje University Haeundae Paik Hospital (KR), Pusan National University Hospital (KR), Busan Medical Center (KR), Hankuk University of Foreign Studies (KR)
Decent work and economic growth
Openalex Percentile: Top 40%
Vestibular and auditory disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.