Can AI substitute the first reader in chest radiograph screening? A retrospective non-inferiority evaluation

To evaluate whether AI can substitute for the first reader in a double-reading workflow for lung-cancer detection on screening chest radiographs. A retrospective analysis was conducted in a screening cohort at Ishikawa Health Service Association that included 155,503 participants undergoing 320,329 examinations between January 2018 and September 2020. From examinations initially identified as suspected lung cancer by the conventional double-reading system (n = 2,882), prespecified exclusions were applied, yielding 1,847 examinations for detection-performance analysis. AI-based lesion detection was retrospectively performed using three AI models, and the localization accuracy of the AI outputs was evaluated. Detection performance (AI vs. first readers) was compared using McNemar’s test with a non-inferiority margin of − 0.05 (AI deemed non-inferior if the lower bound of the 95% CI exceeded − 0.05) in two settings: (1) all lesions and (2) pulmonary nodule/mass only. The false-positive rate per examination was estimated using 5,784 normal examinations (5,689 participants) performed between January and June 2018 with ≥ 2-year negative follow-up. For all abnormalities, each AI model met the non-inferiority criterion relative to first readers and showed higher detection rates (AI detection, 62.5–77.3%; first readers, 59.3%). Similar findings were observed when the analysis was limited to nodule/mass only (AI, 64.5–76.5%; first readers, 59.2%). False-positive frequencies per examination were 0.081 (Software A), 0.065 (Software B), and 0.147 (Software C), versus 0.002 for first readers. In a retrospective screening cohort, three AI models achieved non-inferior, overall higher detection performance compared with first readers for suspected lung cancer on chest radiographs. Despite higher false-positive rates, AI could feasibly assume the first-reader role within a conventional double-reading workflow while maintaining diagnostic quality. Prospective, multi-center studies are warranted to confirm effectiveness, quantify workflow impact, and assess downstream consequences of AI-assisted single reading.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Radiology
Published
2026-03-14
DOI
https://doi.org/10.1007/s11604-026-01973-z
Primary Topic
COVID-19 diagnosis using AI
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can AI substitute the first reader in chest radiograph screening? A retrospective non-inferiority evaluation

Rie Tanaka, Satoshi Kobayashi, Kotaro Yoshida, Tetsuo Matsunaga et al.
Japanese Journal of Radiology
COVID-19 diagnosis using AI
article

Can AI substitute the first reader in chest radiograph screening? A retrospective non-inferiority evaluation

Rie Tanaka, Satoshi Kobayashi, Kotaro Yoshida, Tetsuo Matsunaga, Aya Tonouchi, Atsushi Takamatsu, Antoine Choppin, Takeshi Kobayashi
article en

Abstract

To evaluate whether AI can substitute for the first reader in a double-reading workflow for lung-cancer detection on screening chest radiographs. A retrospective analysis was conducted in a screening cohort at Ishikawa Health Service Association that included 155,503 participants undergoing 320,329 examinations between January 2018 and September 2020. From examinations initially identified as suspected lung cancer by the conventional double-reading system (n = 2,882), prespecified exclusions were applied, yielding 1,847 examinations for detection-performance analysis. AI-based lesion detection was retrospectively performed using three AI models, and the localization accuracy of the AI outputs was evaluated. Detection performance (AI vs. first readers) was compared using McNemar’s test with a non-inferiority margin of − 0.05 (AI deemed non-inferior if the lower bound of the 95% CI exceeded − 0.05) in two settings: (1) all lesions and (2) pulmonary nodule/mass only. The false-positive rate per examination was estimated using 5,784 normal examinations (5,689 participants) performed between January and June 2018 with ≥ 2-year negative follow-up. For all abnormalities, each AI model met the non-inferiority criterion relative to first readers and showed higher detection rates (AI detection, 62.5–77.3%; first readers, 59.3%). Similar findings were observed when the analysis was limited to nodule/mass only (AI, 64.5–76.5%; first readers, 59.2%). False-positive frequencies per examination were 0.081 (Software A), 0.065 (Software B), and 0.147 (Software C), versus 0.002 for first readers. In a retrospective screening cohort, three AI models achieved non-inferior, overall higher detection performance compared with first readers for suspected lung cancer on chest radiographs. Despite higher false-positive rates, AI could feasibly assume the first-reader role within a conventional double-reading workflow while maintaining diagnostic quality. Prospective, multi-center studies are warranted to confirm effectiveness, quantify workflow impact, and assess downstream consequences of AI-assisted single reading.

Japanese Journal of Radiology
Kanazawa University (JP), Exelixis (United States) (US), Kanazawa Medical University (JP), Fukui Prefectural Hospital (JP), Ishikawa Prefectural Central Hospital (JP), Industrial Research Institute of Ishikawa (JP)
Openalex Percentile: Top 24%
COVID-19 diagnosis using AI
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.