Bioethanol fireplaces as indoor pollution sources: The role of burner design and fuel type
Bioethanol fireplaces are marketed as clean and decorative heating alternatives. However, their impact on indoor air quality (IAQ) remains poorly characterised. This study investigates the indoor levels of gaseous and particulate pollutants using a bioethanol fireplace operated under realistic conditions. Two types of bioethanol fuels and two burner designs, a single-chambered (SC) and a double-chambered (DC), were tested under minimal ventilation. Concentrations of CO, NO, NO<sub>2</sub>, CO<sub>2</sub>, NH<sub>3</sub>, N<sub>2</sub>O, C<sub>2</sub>H<sub>6</sub>O, total volatile organic compounds (TVOCs), and carbonyl compounds were measured, while particulate matter (PM<sub>10</sub>) was characterised chemically and toxicologically. Combustion of both fuels led to substantial increases in indoor pollutant concentrations compared to background levels. Indoors, maximum average CO levels reached 5.67 µg m<sup>-3</sup>, NO 0.33 µg m<sup>-3</sup>, NO<sub>2</sub> 0.85 µg m<sup>-3</sup> and TVOCs exceeded 1400 µg m<sup>-3</sup>. Acetaldehyde and formaldehyde were the dominant carbonyls, with the latter frequently surpassing the WHO guideline value along with NO<sub>2</sub>. Compared with traditional wood combustion, bioethanol combustion produced relatively higher indoor concentrations of nitrogen oxides, acetaldehyde, and formaldehyde. Average PM<sub>10</sub> concentrations ranged from 31.5 to 173 µg m<sup>-3</sup>, with higher indoor concentrations for the DC burner and Fuel 2. PM<sub>10</sub> samples were enriched in bromine, ammonium and nitrate during combustion, and exhibited elevated oxidative potential. Differences in indoor pollutant levels and oxidative potential were observed depending on the burner design, fuel type and initial fuel load. These results demonstrate that flueless bioethanol fireplaces can markedly deteriorate IAQ, underscoring the need for performance standards, improved fuel formulations, and adequate ventilation to mitigate exposure risks associated with their use.
Authors
- Jiří Ryšavý (ORCID: https://orcid.org/0000-0003-0175-8668)
- Yago Alonso Cipoli (ORCID: https://orcid.org/0000-0002-2818-4409)
- Eduardo Yubero (ORCID: https://orcid.org/0000-0002-2838-4945)
- Manuel Feliciano (ORCID: https://orcid.org/0000-0002-3147-4511)
- Nuria Galindo (ORCID: https://orcid.org/0000-0003-2058-8465)
- Tiago Nunes
- Estela D. Vicente
- Célia A. Alves
- Isabella Charres
- Mário Cerqueira
Institutions
- Universitat de Miguel Hernández d'Elx (ES)
- VSB - Technical University of Ostrava (CZ)
- Universidade Politécnica de Bragança (PT)
- University of Aveiro (PT)
Publication Details
- Journal
- Journal of Hazardous Materials
- Published
- 2026-03-13
- DOI
- https://doi.org/10.1016/j.jhazmat.2026.141770
- Primary Topic
- Indoor Air Quality and Microbial Exposure
- Type
- article
- Field-Weighted Citation Impact
- 0.00