Characterization of external defibrillator output and its impact on defibrillation protection of medical equipment

Defibrillators constitute a critical component of emergency care for ventricular fibrillation and pulseless ventricular tachycardia. Advances in defibrillation technology point to the potential need for reassessing current requirements for defibrillation protection and associated resuscitation guidelines. This study aimed to establish reference information for future directions in defibrillator requirements, defibrillation protection requirements, and resuscitation guidelines based on the parameters of commercially available defibrillators. Defibrillator brands were identified from the registration records of the China National Medical Products Administration, the U.S. Food and Drug Administration, and the European Database on Medical Devices. Key defibrillation parameters were obtained from publicly available manufacturer documentation. A total of 31 manufacturers and 115 external defibrillators were identified. All studied devices employ biphasic waveforms, with biphasic truncated exponential being the most common, appearing in products from 24 of 31 manufacturers (77.4%). Except for pulsed biphasic devices manufactured by Schiller, maximum output voltages are below 3 kV. Maximum energy limits vary across devices, with some models retaining an upper limit of 360 J. Incorporating biphasic waveforms into defibrillation protection tests may be appropriate. Adjustments to the requirements and guidelines of defibrillation voltage or energy could be considered, depending on market trends and future studies on defibrillation efficacy.

Authors

Institutions

Publication Details

Journal
Resuscitation Plus
Published
2026-03-12
DOI
https://doi.org/10.1016/j.resplu.2026.101289
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of external defibrillator output and its impact on defibrillation protection of medical equipment

Dian Zhang, Jin Deng, Yong Yin
Resuscitation Plus
Cardiac Arrest and Resuscitation
article

Characterization of external defibrillator output and its impact on defibrillation protection of medical equipment

Dian Zhang, Jin Deng, Yong Yin
article en

Abstract

Defibrillators constitute a critical component of emergency care for ventricular fibrillation and pulseless ventricular tachycardia. Advances in defibrillation technology point to the potential need for reassessing current requirements for defibrillation protection and associated resuscitation guidelines. This study aimed to establish reference information for future directions in defibrillator requirements, defibrillation protection requirements, and resuscitation guidelines based on the parameters of commercially available defibrillators. Defibrillator brands were identified from the registration records of the China National Medical Products Administration, the U.S. Food and Drug Administration, and the European Database on Medical Devices. Key defibrillation parameters were obtained from publicly available manufacturer documentation. A total of 31 manufacturers and 115 external defibrillators were identified. All studied devices employ biphasic waveforms, with biphasic truncated exponential being the most common, appearing in products from 24 of 31 manufacturers (77.4%). Except for pulsed biphasic devices manufactured by Schiller, maximum output voltages are below 3 kV. Maximum energy limits vary across devices, with some models retaining an upper limit of 360 J. Incorporating biphasic waveforms into defibrillation protection tests may be appropriate. Adjustments to the requirements and guidelines of defibrillation voltage or energy could be considered, depending on market trends and future studies on defibrillation efficacy.

Resuscitation PlusVol. 29
Hong Kong Standards and Testing Centre (China) (CN)
Good health and well-being
Openalex Percentile: Top 28%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of external defibrillator output and its impact on defibrillation protection of medical equipment — Dian Zhang, Jin Deng, et al. · Resuscitation Plus (2026) | TGRS Research Map | TGRS