IMU-Based Wearable Insoles in Clinical Settings: Key Parameters Differentiating Clinical and Non-Clinical Populations

Wearable systems based on inertial measurement units (IMUs) have attracted considerable interest in recent years in the field of gait analysis. However, most gait studies using such devices have been conducted in laboratory rather than clinical settings. This study evaluated a commercially available IMU-based insole system in two cohorts: a clinical group (59 ± 18, years) recruited from podiatry clinics and a non-clinical group (28 ± 7, years) recruited from a university with no reported complaints. Participants wore the IMU-based device and performed treadmill walking (clinical group) and overground walking (non-clinical group). Spatiotemporal parameters were compared between groups using statistical analyses included the Shapiro-Wilk test, Mann-Whitney test, and Welch's <i>t</i>-tests for non-bilateral data, and a two-factor linear mixed-effects model estimated by restricted maximum likelihood (REML) for bilateral spatiotemporal parameters to evaluate group, foot-side, and interaction effects. Ten of the twenty-two spatiotemporal parameters showed significant group differences, with statistical significance observed in at least one foot for parameters measured bilaterally. The observed differences may reflect a combination of clinical characteristics, age-related effects, and walking environment influences. Findings are discussed in relation to potential biomechanical mechanisms, factors influencing results and the clinical utility of IMU systems. Future research should investigate specific foot conditions under standardized walking conditions with age-matched cohorts.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-03-12
DOI
https://doi.org/10.3390/s26061802
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMU-Based Wearable Insoles in Clinical Settings: Key Parameters Differentiating Clinical and Non-Clinical Populations

Guqi Wang, Dean S. Hartley, Kerrie Evans, Scott Morrison et al.
Sensors
Lower Extremity Biomechanics and Pathologies
article

IMU-Based Wearable Insoles in Clinical Settings: Key Parameters Differentiating Clinical and Non-Clinical Populations

Guqi Wang, Dean S. Hartley, Kerrie Evans, Scott Morrison, Stuart D. McDonald, Martin Veidt, Sheng Lin
article en

Abstract

Wearable systems based on inertial measurement units (IMUs) have attracted considerable interest in recent years in the field of gait analysis. However, most gait studies using such devices have been conducted in laboratory rather than clinical settings. This study evaluated a commercially available IMU-based insole system in two cohorts: a clinical group (59 ± 18, years) recruited from podiatry clinics and a non-clinical group (28 ± 7, years) recruited from a university with no reported complaints. Participants wore the IMU-based device and performed treadmill walking (clinical group) and overground walking (non-clinical group). Spatiotemporal parameters were compared between groups using statistical analyses included the Shapiro-Wilk test, Mann-Whitney test, and Welch's <i>t</i>-tests for non-bilateral data, and a two-factor linear mixed-effects model estimated by restricted maximum likelihood (REML) for bilateral spatiotemporal parameters to evaluate group, foot-side, and interaction effects. Ten of the twenty-two spatiotemporal parameters showed significant group differences, with statistical significance observed in at least one foot for parameters measured bilaterally. The observed differences may reflect a combination of clinical characteristics, age-related effects, and walking environment influences. Findings are discussed in relation to potential biomechanical mechanisms, factors influencing results and the clinical utility of IMU systems. Future research should investigate specific foot conditions under standardized walking conditions with age-matched cohorts.

SensorsVol. 26(6)
The University of Sydney (AU), The University of Queensland (AU), Australian Football League (AU), Henan Academy of Sciences (CN)
Department of Industry and Science, Australian Government, Cooperative Research Centres, Australian Government Department of Industry, Coral Reef Conservation Program
Openalex Percentile: Top 24%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.