Usability evaluation of smartphone-based goniometer applications for shoulder range of motion

Range of motion (ROM) measurements are performed every day in clinical practice. The ROM is usually measured using conventional goniometers; however, studies have shown considerable variability in interrater and intrarater reliability. Despite the growing availability of smartphone-based goniometry, studies on the usability of these tools are highly limited. The aim of this study was to evaluate shoulder ROM applications (apps), with a focus on their usability and handling. Eleven apps were identified and tested by two physicians using the same smartphone. A healthy volunteer subject performed defined movements with each arm measured three times per app by both users. The apps were evaluated in terms of usability on a grading scale, with 1 representing the best result and 6 representing the worst result, on the basis of two key factors: intuitiveness and quality of description. The learning time of the physicians was also measured and recorded in minutes. The usability of the apps showed considerable variability. The usability is statistically correlated with the learning time of the raters (p = 0.021; τb = 0.607 for quality of description and p = 0.039; τb = 0.551 for intuitiveness). The quality of description and intuitiveness are significantly correlated with each other (p < 0.001; τb = 0.941). The interrater reliability was high, with an ICC of 0.88 for the quality of the description and 0.95 for intuitiveness, suggesting consistent evaluations between the raters. Two apps were rated as the best apps, with 1.0 and 1.25 in usability. Overall, there seems to be wide variation in the usability of smartphone-based apps. While smartphone-based goniometers show potential benefits, further research is required to establish their applicability before routine use.

Authors

Institutions

Publication Details

Journal
BMC Digital Health
Published
2026-03-12
DOI
https://doi.org/10.1186/s44247-026-00250-3
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Usability evaluation of smartphone-based goniometer applications for shoulder range of motion

Henry Gebauer, David Alexander Back, Poroshista Knauer, Rony-Orijit Dey Hazra et al.
BMC Digital Health
Shoulder Injury and Treatment
article

Usability evaluation of smartphone-based goniometer applications for shoulder range of motion

Henry Gebauer, David Alexander Back, Poroshista Knauer, Rony-Orijit Dey Hazra, Elisa Marie Planatscher, Doruk Akgün, Gernot Steiner
article en

Abstract

Range of motion (ROM) measurements are performed every day in clinical practice. The ROM is usually measured using conventional goniometers; however, studies have shown considerable variability in interrater and intrarater reliability. Despite the growing availability of smartphone-based goniometry, studies on the usability of these tools are highly limited. The aim of this study was to evaluate shoulder ROM applications (apps), with a focus on their usability and handling. Eleven apps were identified and tested by two physicians using the same smartphone. A healthy volunteer subject performed defined movements with each arm measured three times per app by both users. The apps were evaluated in terms of usability on a grading scale, with 1 representing the best result and 6 representing the worst result, on the basis of two key factors: intuitiveness and quality of description. The learning time of the physicians was also measured and recorded in minutes. The usability of the apps showed considerable variability. The usability is statistically correlated with the learning time of the raters (p = 0.021; τb = 0.607 for quality of description and p = 0.039; τb = 0.551 for intuitiveness). The quality of description and intuitiveness are significantly correlated with each other (p < 0.001; τb = 0.941). The interrater reliability was high, with an ICC of 0.88 for the quality of the description and 0.95 for intuitiveness, suggesting consistent evaluations between the raters. Two apps were rated as the best apps, with 1.0 and 1.25 in usability. Overall, there seems to be wide variation in the usability of smartphone-based apps. While smartphone-based goniometers show potential benefits, further research is required to establish their applicability before routine use.

BMC Digital HealthVol. 4(1)
Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 24%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Usability evaluation of smartphone-based goniometer applications for shoulder range of motion — Henry Gebauer, David Alexander Back, et al. · BMC Digital Health (2026) | TGRS Research Map | TGRS