Efficacy and safety of a novel pulsed field ablation system in paroxysmal atrial fibrillation

Pulsed field ablation (PFA) is an emerging innovative technology for treating paroxysmal atrial fibrillation (PAF), featured by its superior speed, accuracy, and reduced risk to adjacent tissues. The NOVA-AF study aimed to evaluate the efficacy and safety of a novel PFA system equipped with two PFA catheters: a circular PFA catheter and a linear PFA catheter integrating contact force-sensing capability, in patients with symptomatic PAF. This prospective, multicenter, single-arm study enrolled 161 patients with symptomatic PAF from seven medical centers in China. The composite primary effectiveness endpoint was defined as freedom from atrial tachyarrhythmia recurrence, device failure, multiple ablations during the blanking period, or antiarrhythmic drug failure during the evaluation period. The primary safety endpoint was the incidence of major adverse events (MAEs) related to the devices or procedures within three months of the procedure. All the ablated lesions (100%) were acutely electrically isolated. No patients underwent repeat ablation during the 90-day blanking period. The 12-month Kaplan–Meier estimates for primary effectiveness success and clinical success (absence of symptomatic atrial fibrillation recurrence) were 83.0% (95% confidence interval, 76.2%–88.0%) and 94.9%, respectively. No MAEs occurred. This novel PFA system is effective and safe for the ablation treatment of patients with symptomatic PAF. Chinese Clinical Trial Registry ( www.chictr.org.cn ), TRN: ChiCTR2400091941, Registration date: Nov 6 2024 (retrospectively registered).

Authors

Institutions

Publication Details

Journal
Journal of Interventional Cardiac Electrophysiology
Published
2026-03-12
DOI
https://doi.org/10.1007/s10840-026-02284-z
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and safety of a novel pulsed field ablation system in paroxysmal atrial fibrillation

Hanxiong Liu, Gang Yang, Jianhua Yu, Zhihui Zhang et al.
Journal of Interventional Cardiac Electrophysiology
Atrial Fibrillation Management and Outcomes
article

Efficacy and safety of a novel pulsed field ablation system in paroxysmal atrial fibrillation

Hanxiong Liu, Gang Yang, Jianhua Yu, Zhihui Zhang, Wenzhi Luo, Jinzhu Hu, Zhenjiang Liu, Qinmei Xiong, Zhiyu Ling, Qiming Liu, Yan Wang, Shenghua Zhou, Yan Luo, Zhen Zhang, Chenyang Jiang, Duan Luo, Qi Chen, Xiaoshu Cheng, Xuping Li, Juying Zhang
article en

Abstract

Pulsed field ablation (PFA) is an emerging innovative technology for treating paroxysmal atrial fibrillation (PAF), featured by its superior speed, accuracy, and reduced risk to adjacent tissues. The NOVA-AF study aimed to evaluate the efficacy and safety of a novel PFA system equipped with two PFA catheters: a circular PFA catheter and a linear PFA catheter integrating contact force-sensing capability, in patients with symptomatic PAF. This prospective, multicenter, single-arm study enrolled 161 patients with symptomatic PAF from seven medical centers in China. The composite primary effectiveness endpoint was defined as freedom from atrial tachyarrhythmia recurrence, device failure, multiple ablations during the blanking period, or antiarrhythmic drug failure during the evaluation period. The primary safety endpoint was the incidence of major adverse events (MAEs) related to the devices or procedures within three months of the procedure. All the ablated lesions (100%) were acutely electrically isolated. No patients underwent repeat ablation during the 90-day blanking period. The 12-month Kaplan–Meier estimates for primary effectiveness success and clinical success (absence of symptomatic atrial fibrillation recurrence) were 83.0% (95% confidence interval, 76.2%–88.0%) and 94.9%, respectively. No MAEs occurred. This novel PFA system is effective and safe for the ablation treatment of patients with symptomatic PAF. Chinese Clinical Trial Registry ( www.chictr.org.cn ), TRN: ChiCTR2400091941, Registration date: Nov 6 2024 (retrospectively registered).

Journal of Interventional Cardiac Electrophysiology
Central South University (CN), Nanchang University (CN), Dalian Medical University (CN), Sichuan University (CN), Sir Run Run Shaw Hospital (CN), Third People's Hospital of Chengdu (CN), Second Affiliated Hospital of Chongqing Medical University (CN), Second Affiliated Hospital of Nanchang University (CN), Second Xiangya Hospital of Central South University (CN), Third Xiangya Hospital (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN), Zhejiang University (CN), Chongqing Medical University (CN)
Openalex Percentile: Top 32%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.