Research on Ultra‐Wideband Pulse Current Method for DC Partial Discharge Measurement

ABSTRACT The conventional pulse current method is commonly used in AC or DC withstand voltage tests with partial discharge (PD) monitoring. Because of its relatively narrow measurement bandwidth, this method tends to ignore critical information in PD waveforms, making it difficult to eliminate pulse‐type interference under DC voltage conditions, where phase information is absent. To enhance interference rejection and achieve effective separation of multiple PD sources under DC voltage, an ultra‐wideband pulse current method was proposed. A detection impedance was developed to extend the upper limit of the measurement bandwidth to 50 MHz to retain PD waveform information. PD waveforms measured from three defect models using both the conventional pulse current method and the ultra‐wideband method were analysed in both time and frequency domains. The criterion function was employed to evaluate the difficulty level of classification of the PD waveforms obtained by the two measurement methods, and the results were validated using equivalent time–frequency (T–F) spectra. Field interference waveforms were introduced, and the density‐based spatial clustering of applications with noise (DBSCAN) clustering method was applied for unsupervised clustering of the PD waveforms and interference waveforms. The results demonstrate that the ultra‐wideband method can effectively separate multiple PD sources and eliminate interference sources under DC voltage conditions.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2026-03-12
DOI
https://doi.org/10.1049/hve2.70175
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Ultra‐Wideband Pulse Current Method for DC Partial Discharge Measurement

Zhaoyang Kang, Kaining Hou, Dongxin He, Qingquan Li et al.
High Voltage
High voltage insulation and dielectric phenomena
article

Research on Ultra‐Wideband Pulse Current Method for DC Partial Discharge Measurement

Zhaoyang Kang, Kaining Hou, Dongxin He, Qingquan Li, Hongshun Liu
article en

Abstract

ABSTRACT The conventional pulse current method is commonly used in AC or DC withstand voltage tests with partial discharge (PD) monitoring. Because of its relatively narrow measurement bandwidth, this method tends to ignore critical information in PD waveforms, making it difficult to eliminate pulse‐type interference under DC voltage conditions, where phase information is absent. To enhance interference rejection and achieve effective separation of multiple PD sources under DC voltage, an ultra‐wideband pulse current method was proposed. A detection impedance was developed to extend the upper limit of the measurement bandwidth to 50 MHz to retain PD waveform information. PD waveforms measured from three defect models using both the conventional pulse current method and the ultra‐wideband method were analysed in both time and frequency domains. The criterion function was employed to evaluate the difficulty level of classification of the PD waveforms obtained by the two measurement methods, and the results were validated using equivalent time–frequency (T–F) spectra. Field interference waveforms were introduced, and the density‐based spatial clustering of applications with noise (DBSCAN) clustering method was applied for unsupervised clustering of the PD waveforms and interference waveforms. The results demonstrate that the ultra‐wideband method can effectively separate multiple PD sources and eliminate interference sources under DC voltage conditions.

High Voltage
Shandong University (CN), Shandong Special Equipment Inspection Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 25%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.