A Chemiresistive Nanosensor Array for Rapid and Sensitive VOC-Based Detection and Differentiation of Prosthetic Joint Infection-Relevant Pathogens in Enriched Human Synovial Fluid

Rapid and actionable pathogen identification remains a major unmet need in the diagnosis of prosthetic joint infection (PJI). Current diagnostic approaches either provide rapid host response information without pathogen specificity or identify pathogens with delays of days to weeks. Here, we report a chemiresistive nanosensor array combined with machine learning analysis for same-day, pathogen-specific detection based on volatile organic compound (VOC) profiling. A 19-channel nanosensor array was first validated in vitro against a panel of ESKAPEE pathogens, achieving 96% mean classification accuracy using a radial-basis-function support vector machine (SVM) classifier. Data-driven optimization yielded a reduced six-sensor array with high signal-to-noise performance. The optimized platform was evaluated using pooled, uninfected human synovial fluid enriched 1:1 with nutrient media and spiked with <i>Staphylococcus aureus</i>, <i>Staphylococcus epidermidis</i>, or <i>Pseudomonas aeruginosa</i> across a range of 1-10<sup>6</sup> CFU/mL. All infected samples were detected within 9 h, with distinct VOC signatures enabling accurate pathogen differentiation. Time-to-detection (TTD) demonstrated a strong inverse correlation with initial bacterial concentration, supporting semi-quantitative estimation of bacterial load. Negative controls remained at baseline throughout testing. This chemiresistive VOC-based biosensor platform demonstrates the potential to deliver rapid, integrated detection, identification, and burden estimation of metabolically active PJI pathogens, highlighting its promise for future point-of-care diagnostic applications.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-03-12
DOI
https://doi.org/10.3390/bios16030156
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Chemiresistive Nanosensor Array for Rapid and Sensitive VOC-Based Detection and Differentiation of Prosthetic Joint Infection-Relevant Pathogens in Enriched Human Synovial Fluid

Subramaniam Somasundaram, Derese Getnet, XiaoNao Liu, Krista Toler et al.
Biosensors
Advanced Chemical Sensor Technologies
article

A Chemiresistive Nanosensor Array for Rapid and Sensitive VOC-Based Detection and Differentiation of Prosthetic Joint Infection-Relevant Pathogens in Enriched Human Synovial Fluid

Subramaniam Somasundaram, Derese Getnet, XiaoNao Liu, Krista Toler, Jennifer N. Dootz, Taejun Ko, Venkatasivasai Sujith Sajja, Deyu Liu, Mya Wilkes, Robert Hopkins, Buyu Yeh
article en

Abstract

Rapid and actionable pathogen identification remains a major unmet need in the diagnosis of prosthetic joint infection (PJI). Current diagnostic approaches either provide rapid host response information without pathogen specificity or identify pathogens with delays of days to weeks. Here, we report a chemiresistive nanosensor array combined with machine learning analysis for same-day, pathogen-specific detection based on volatile organic compound (VOC) profiling. A 19-channel nanosensor array was first validated in vitro against a panel of ESKAPEE pathogens, achieving 96% mean classification accuracy using a radial-basis-function support vector machine (SVM) classifier. Data-driven optimization yielded a reduced six-sensor array with high signal-to-noise performance. The optimized platform was evaluated using pooled, uninfected human synovial fluid enriched 1:1 with nutrient media and spiked with <i>Staphylococcus aureus</i>, <i>Staphylococcus epidermidis</i>, or <i>Pseudomonas aeruginosa</i> across a range of 1-10<sup>6</sup> CFU/mL. All infected samples were detected within 9 h, with distinct VOC signatures enabling accurate pathogen differentiation. Time-to-detection (TTD) demonstrated a strong inverse correlation with initial bacterial concentration, supporting semi-quantitative estimation of bacterial load. Negative controls remained at baseline throughout testing. This chemiresistive VOC-based biosensor platform demonstrates the potential to deliver rapid, integrated detection, identification, and burden estimation of metabolically active PJI pathogens, highlighting its promise for future point-of-care diagnostic applications.

BiosensorsVol. 16(3)
Telemedicine & Advanced Technology Research Center (US), Zimmer Biomet (United States) (US)
Openalex Percentile: Top 24%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.