DC Series Arc Detection Algorithm Using FFT-Based Frequency Band Analysis and RMS Current Variations

With the increasing penetration of renewable energy, the detection of DC series arcs has become increasingly critical in DC power systems. This paper proposes an arc detection algorithm that uses frequency-band variations of current signals. Current data sampled at 100 [kHz] are processed using a sliding FFT (Fast Fourier Transform) and divided into seven bands spanning 0–50 [kHz]. The RMS current for each band is computed per frame, the absolute frame-to-frame difference is calculated, and the result is normalized using the Z-score method. An arc is declared if the metric exceeds a threshold within a detection window. DC series arc tests conducted under four load conditions and eight electrode opening speeds show pronounced changes in the 0.2–1 [kHz] and 1–5 [kHz] bands. The 1–5 [kHz] band, being less dependent on load yet sensitive to arcs, is selected for the algorithm. The proposed method detected arcs within 0.15 seconds across all tested conditions.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2026-03-13
DOI
https://doi.org/10.5370/kiee.2026.75.3.629
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC Series Arc Detection Algorithm Using FFT-Based Frequency Band Analysis and RMS Current Variations

Sung-Hun Lim, Min-Ho Yoon, Chan-Muk Park
The Transactions of The Korean Institute of Electrical Engineers
Electrical Fault Detection and Protection
article

DC Series Arc Detection Algorithm Using FFT-Based Frequency Band Analysis and RMS Current Variations

Sung-Hun Lim, Min-Ho Yoon, Chan-Muk Park
article en

Abstract

With the increasing penetration of renewable energy, the detection of DC series arcs has become increasingly critical in DC power systems. This paper proposes an arc detection algorithm that uses frequency-band variations of current signals. Current data sampled at 100 [kHz] are processed using a sliding FFT (Fast Fourier Transform) and divided into seven bands spanning 0–50 [kHz]. The RMS current for each band is computed per frame, the absolute frame-to-frame difference is calculated, and the result is normalized using the Z-score method. An arc is declared if the metric exceeds a threshold within a detection window. DC series arc tests conducted under four load conditions and eight electrode opening speeds show pronounced changes in the 0.2–1 [kHz] and 1–5 [kHz] bands. The 1–5 [kHz] band, being less dependent on load yet sensitive to arcs, is selected for the algorithm. The proposed method detected arcs within 0.15 seconds across all tested conditions.

The Transactions of The Korean Institute of Electrical EngineersVol. 75(3)
Affordable and clean energy
Openalex Percentile: Top 24%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.