Enhanced data usability in dynamic 68 Ga-PSMA-11 PET of intracranial tumors using a dynamic head motion correction algorithm

Head motion during dynamic positron emission tomography (dPET) compromises pharmacokinetic modeling, especially in prolonged acquisitions where motion artifacts invalidate quantitative analysis. Although motion correction methods are well-established for static PET, their application in dynamic imaging remains limited. This study evaluates the efficacy of a data-driven dynamic head motion correction (dHMC) algorithm in preserving the reliability of kinetic parameter, using dynamic 68 Ga-PSMA-11 PET of intracranial tumors as a challenging model due to the tracer’s inability to cross the blood–brain barrier, unlike the diffusely distributed 18F-FDG used in prior studies. Sixteen patients with suspected glioma based on preoperative imaging underwent 40-min dynamic 68 Ga-PSMA-11 PET head scans. Head motion was categorized into minor and high-motion groups based on maximum displacement (> 3 mm) or time-weighted mean displacement (> 2 mm) within the tumor region. The performance of dHMC was evaluated in tumor and reference organs (parotid and lacrimal glands) based on fitting metrics, including the coefficient of determination (R2) and Akaike information criterion (AIC), and quantitative kinetic parameters. Time-activity curves (TACs) and key kinetic parameters (k2 and k3) were generated using an irreversible two-tissue compartment model (2T3k). dHMC robustly corrected motion-induced inaccuracies across motion levels, enabling analysis in 43.75% of previously non-analyzable cases. The algorithm yielded three major improvements without introducing bias: First, it significantly enhanced pharmacokinetic modeling fidelity, evidenced by smoother TACs, along with increased R2 values of 8.35%, 4.54%, and 30.9% in tumor, parotid, and lacrimal glands, respectively, and reduced AIC values by 6.95%, 5.33%, and 13.32%. Second, it improved the accuracy and homogeneity of k2 and k3 estimates in reference organs, indicated by significantly reduced data dispersion. Third, it brought the quantitative parameters of the parotid gland closer to established reference standards. All improvements were most pronounced in high-motion cases. The dHMC algorithm enhances fitting performance, parametric accuracy, and inter-frame consistency in dynamic 68 Ga-PSMA-11 PET, validating its broad applicability across varying motion scenarios and underscoring the essential role of motion correction in maintaining quantitative accuracy in dPET.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-03-12
DOI
https://doi.org/10.1186/s40658-026-00843-x
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced data usability in dynamic 68 Ga-PSMA-11 PET of intracranial tumors using a dynamic head motion correction algorithm

Guiyu Li, Ying Guo, Taoqi Ma, Fei Kang et al.
EJNMMI Physics
Medical Imaging Techniques and Applications
article

Enhanced data usability in dynamic 68 Ga-PSMA-11 PET of intracranial tumors using a dynamic head motion correction algorithm

Guiyu Li, Ying Guo, Taoqi Ma, Fei Kang, Jing Wang, Risheng Yang, Kun Guo
article en

Abstract

Head motion during dynamic positron emission tomography (dPET) compromises pharmacokinetic modeling, especially in prolonged acquisitions where motion artifacts invalidate quantitative analysis. Although motion correction methods are well-established for static PET, their application in dynamic imaging remains limited. This study evaluates the efficacy of a data-driven dynamic head motion correction (dHMC) algorithm in preserving the reliability of kinetic parameter, using dynamic 68 Ga-PSMA-11 PET of intracranial tumors as a challenging model due to the tracer’s inability to cross the blood–brain barrier, unlike the diffusely distributed 18F-FDG used in prior studies. Sixteen patients with suspected glioma based on preoperative imaging underwent 40-min dynamic 68 Ga-PSMA-11 PET head scans. Head motion was categorized into minor and high-motion groups based on maximum displacement (> 3 mm) or time-weighted mean displacement (> 2 mm) within the tumor region. The performance of dHMC was evaluated in tumor and reference organs (parotid and lacrimal glands) based on fitting metrics, including the coefficient of determination (R2) and Akaike information criterion (AIC), and quantitative kinetic parameters. Time-activity curves (TACs) and key kinetic parameters (k2 and k3) were generated using an irreversible two-tissue compartment model (2T3k). dHMC robustly corrected motion-induced inaccuracies across motion levels, enabling analysis in 43.75% of previously non-analyzable cases. The algorithm yielded three major improvements without introducing bias: First, it significantly enhanced pharmacokinetic modeling fidelity, evidenced by smoother TACs, along with increased R2 values of 8.35%, 4.54%, and 30.9% in tumor, parotid, and lacrimal glands, respectively, and reduced AIC values by 6.95%, 5.33%, and 13.32%. Second, it improved the accuracy and homogeneity of k2 and k3 estimates in reference organs, indicated by significantly reduced data dispersion. Third, it brought the quantitative parameters of the parotid gland closer to established reference standards. All improvements were most pronounced in high-motion cases. The dHMC algorithm enhances fitting performance, parametric accuracy, and inter-frame consistency in dynamic 68 Ga-PSMA-11 PET, validating its broad applicability across varying motion scenarios and underscoring the essential role of motion correction in maintaining quantitative accuracy in dPET.

EJNMMI Physics
Command Hospital Air Force (IN), Xijing Hospital (CN), Air Force Medical University (CN)
Openalex Percentile: Top 25%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.