Comparison of Noninvasive Inhaled Nitric Oxide Delivery Methods in an Infant Model

Background: Inhaled nitric oxide (iNO) is frequently delivered with noninvasive methods at our institution for children with congenital heart disease. This includes a high-flow nasal cannula (HFNC) system and noninvasive ventilation (NIV). Previous evaluation of iNO delivery via HFNC in an infant model found that delivery efficiency ranged from 63-78% (Berlinski A, Moore M, Willis D. Inhaled nitric oxide delivery in a 7-month-old spontaneously breathing infant model. J Cystic Fibrosis 2023;22(Suppl):S6). The aim of this study was to evaluate iNO delivery with NIV and to compare it to previously obtained data using HFNC system. Methods: An anatomically correct 3D airway model of a 7 month-old child was connected in series to a scavenger filter and breathing simulator (frequency 30 breaths/min, VT 50 mL, I:E 1:2). A nasal cannula (Medium Optiflow Jr 2, Fisher & Paykel) was used with flows 2, 6, and 10 L/min for the HFNC system. NIV was used with a nasal cannula (RAM, Neotech) and ventilator (Servo-i, Getinge) with breathing frequency 30 breaths/min, pressure control 10 cm H2O, and PEEP 8 cm H2O. The iNO system (INOMax, Mallinckrodt) was set to deliver 5, 20, and 40 ppm. NO analyzers were placed before the nasal cannula and at the tracheal level. Delivered and tracheal iNO measurements were recorded after 3 min and experiments were performed in quadruplicate. Ambient NO and NO2 were monitored. Tracheal iNO/dialed iNO(%) values were calculated. ANOVA for repeated measures followed by Tukey for multiple comparisons was used to compare NIV data (different iNO concentrations). Unpaired t-test was used to compare NIV and HFNC data at each iNO concentration. A P < .05 was considered statistically significant. Results: NIV system delivery efficiency ranged from 86-98% and increased with increasing iNO concentration. Tracheal percentage was higher for 5, 20, and 40 ppm with NIV than HFNC at 2 L/min (P < .04), 6 L/min (P < .001), and 10 L/min (P < .001). Ambient NO and NO2 were 0 for all experiments. Conclusions: Delivery of iNO with a NIV system was very efficient. Practitioners should be aware that when transitioning to ventilatory support with HFNC a decrease in iNO delivery efficiency may occur.Experimental Set-up

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2024-10-01
DOI
https://doi.org/10.4187/respcare.20244125905
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Noninvasive Inhaled Nitric Oxide Delivery Methods in an Infant Model

Ariel Berlinski, Denise Willis, Mike Moore
Respiratory Care
Neonatal Respiratory Health Research
article

Comparison of Noninvasive Inhaled Nitric Oxide Delivery Methods in an Infant Model

Ariel Berlinski, Denise Willis, Mike Moore
article en

Abstract

Background: Inhaled nitric oxide (iNO) is frequently delivered with noninvasive methods at our institution for children with congenital heart disease. This includes a high-flow nasal cannula (HFNC) system and noninvasive ventilation (NIV). Previous evaluation of iNO delivery via HFNC in an infant model found that delivery efficiency ranged from 63-78% (Berlinski A, Moore M, Willis D. Inhaled nitric oxide delivery in a 7-month-old spontaneously breathing infant model. J Cystic Fibrosis 2023;22(Suppl):S6). The aim of this study was to evaluate iNO delivery with NIV and to compare it to previously obtained data using HFNC system. Methods: An anatomically correct 3D airway model of a 7 month-old child was connected in series to a scavenger filter and breathing simulator (frequency 30 breaths/min, VT 50 mL, I:E 1:2). A nasal cannula (Medium Optiflow Jr 2, Fisher & Paykel) was used with flows 2, 6, and 10 L/min for the HFNC system. NIV was used with a nasal cannula (RAM, Neotech) and ventilator (Servo-i, Getinge) with breathing frequency 30 breaths/min, pressure control 10 cm H2O, and PEEP 8 cm H2O. The iNO system (INOMax, Mallinckrodt) was set to deliver 5, 20, and 40 ppm. NO analyzers were placed before the nasal cannula and at the tracheal level. Delivered and tracheal iNO measurements were recorded after 3 min and experiments were performed in quadruplicate. Ambient NO and NO2 were monitored. Tracheal iNO/dialed iNO(%) values were calculated. ANOVA for repeated measures followed by Tukey for multiple comparisons was used to compare NIV data (different iNO concentrations). Unpaired t-test was used to compare NIV and HFNC data at each iNO concentration. A P < .05 was considered statistically significant. Results: NIV system delivery efficiency ranged from 86-98% and increased with increasing iNO concentration. Tracheal percentage was higher for 5, 20, and 40 ppm with NIV than HFNC at 2 L/min (P < .04), 6 L/min (P < .001), and 10 L/min (P < .001). Ambient NO and NO2 were 0 for all experiments. Conclusions: Delivery of iNO with a NIV system was very efficient. Practitioners should be aware that when transitioning to ventilatory support with HFNC a decrease in iNO delivery efficiency may occur.Experimental Set-up

Respiratory CareVol. 69(10_suppl)
Arkansas Children's Hospital (US), University of Arkansas for Medical Sciences (US)
Openalex Percentile: Top 41%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.