Precise Lung Density Quantification with a Physics-based CT Harmonizer

Purpose To develop a physics-based image harmonization method that transforms images into a reference quality index of noise, spatial resolution, and lung volume and to evaluate its performance for improving reproducibility of lung density measurement. Materials and Methods This retrospective analysis of Genetic Epidemiology of Chronic Obstructive Pulmonary Disease (COPDGene) study data included participants who underwent chest CT with full-dose (200 mAs) and reduced-dose (40-80 mAs) protocols during the same visit between November 2014 and July 2017. A harmonization algorithm was developed to reduce variations in lung density by adjusting spatial resolution, noise, and lung volume in sequence, aligning scans to a reference condition based on full-dose, soft-kernel reconstruction. The percentage of lung voxels less than -950 HU (LAA-950) and the 15th percentile of the lung density histogram (Perc15) were calculated from scans. Improvements in bias, limits of agreement, and reproducibility coefficients were evaluated, and harmonizer performance was compared with that of two existing techniques: volume-adjusted lung density (VALD) and median filtering followed by VALD (MF-VALD). Results A total of 1159 participants (mean age ± SD, 65 years ± 9; 586 male) were studied. Across all imaging conditions, the harmonization technique improved the Perc15 reproducibility coefficient 4.8-fold, from 35.6 HU ± 0.7 to 7.4 HU ± 0.2. The harmonizer outperformed VALD and MF-VALD across the full-dose and reduced-dose scans, with reproducibility coefficients improving from 32.4 HU ± 0.7 before harmonization to 30.1 HU ± 0.3 with VALD, 10.3 HU ± 0.3 with MF-VALD, and 7.7 HU ± 0.2 with the harmonizer. Conclusion This physics-based technique harmonized CT images to a reference quality index, improving the reproducibility of lung density metrics. <b>Keywords:</b> CT, Thorax, Lung, Physics, Chronic Obstructive Pulmonary Disease Clinical trial registration no. NCT00608764 <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Authors

Institutions

Publication Details

Journal
Radiology Cardiothoracic Imaging
Published
2026-03-12
DOI
https://doi.org/10.1148/ryct.250124
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precise Lung Density Quantification with a Physics-based CT Harmonizer

D. Lynch, E. Abadi, E. Samei, Saman Sotoudeh-Paima et al.
Radiology Cardiothoracic Imaging
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Precise Lung Density Quantification with a Physics-based CT Harmonizer

D. Lynch, E. Abadi, E. Samei, Saman Sotoudeh-Paima, Stephen M. Humphries
article en

Abstract

Purpose To develop a physics-based image harmonization method that transforms images into a reference quality index of noise, spatial resolution, and lung volume and to evaluate its performance for improving reproducibility of lung density measurement. Materials and Methods This retrospective analysis of Genetic Epidemiology of Chronic Obstructive Pulmonary Disease (COPDGene) study data included participants who underwent chest CT with full-dose (200 mAs) and reduced-dose (40-80 mAs) protocols during the same visit between November 2014 and July 2017. A harmonization algorithm was developed to reduce variations in lung density by adjusting spatial resolution, noise, and lung volume in sequence, aligning scans to a reference condition based on full-dose, soft-kernel reconstruction. The percentage of lung voxels less than -950 HU (LAA-950) and the 15th percentile of the lung density histogram (Perc15) were calculated from scans. Improvements in bias, limits of agreement, and reproducibility coefficients were evaluated, and harmonizer performance was compared with that of two existing techniques: volume-adjusted lung density (VALD) and median filtering followed by VALD (MF-VALD). Results A total of 1159 participants (mean age ± SD, 65 years ± 9; 586 male) were studied. Across all imaging conditions, the harmonization technique improved the Perc15 reproducibility coefficient 4.8-fold, from 35.6 HU ± 0.7 to 7.4 HU ± 0.2. The harmonizer outperformed VALD and MF-VALD across the full-dose and reduced-dose scans, with reproducibility coefficients improving from 32.4 HU ± 0.7 before harmonization to 30.1 HU ± 0.3 with VALD, 10.3 HU ± 0.3 with MF-VALD, and 7.7 HU ± 0.2 with the harmonizer. Conclusion This physics-based technique harmonized CT images to a reference quality index, improving the reproducibility of lung density metrics. <b>Keywords:</b> CT, Thorax, Lung, Physics, Chronic Obstructive Pulmonary Disease Clinical trial registration no. NCT00608764 <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Radiology Cardiothoracic ImagingVol. 8(2)
Duke University (US), National Jewish Health (US), Duke Medical Center (US), Advanced Imaging Research (United States) (US), University of Colorado Denver (US)
Good health and well-being
Openalex Percentile: Top 24%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.