Successful Management of a Complex Coronary Bifurcation Lesion in Acute Coronary Syndrome Using a Free‐Metal Approach

We present the case of a 56-year-old male with non-ST elevation myocardial infarction (NSTEMI) and a complex thrombotic lesion at the ostial left circumflex artery (LCX), extending into bifurcating marginal branches. Due to the high risk of side branch occlusion, a stentless strategy using thrombus aspiration, the reverse wire technique, and sequential plaque modification with a cutting balloon (Rodin-CUT technique) was employed. Following optimal lesion preparation, a drug-coated balloon (DCB) was deployed, achieving excellent angiographic and intravascular ultrasound (IVUS) results, with sustained vessel patency at 6-month follow-up. This case highlights the efficacy of a free-metal strategy in managing challenging bifurcation lesions while preserving side branches and avoiding the risks associated with permanent metallic implants.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-03-12
DOI
https://doi.org/10.1002/ccd.70553
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Successful Management of a Complex Coronary Bifurcation Lesion in Acute Coronary Syndrome Using a Free‐Metal Approach

Claudiu Ungureanu, Flavius‐Alexandru Gherasie
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Successful Management of a Complex Coronary Bifurcation Lesion in Acute Coronary Syndrome Using a Free‐Metal Approach

Claudiu Ungureanu, Flavius‐Alexandru Gherasie
article en

Abstract

We present the case of a 56-year-old male with non-ST elevation myocardial infarction (NSTEMI) and a complex thrombotic lesion at the ostial left circumflex artery (LCX), extending into bifurcating marginal branches. Due to the high risk of side branch occlusion, a stentless strategy using thrombus aspiration, the reverse wire technique, and sequential plaque modification with a cutting balloon (Rodin-CUT technique) was employed. Following optimal lesion preparation, a drug-coated balloon (DCB) was deployed, achieving excellent angiographic and intravascular ultrasound (IVUS) results, with sustained vessel patency at 6-month follow-up. This case highlights the efficacy of a free-metal strategy in managing challenging bifurcation lesions while preserving side branches and avoiding the risks associated with permanent metallic implants.

Catheterization and Cardiovascular Interventions
Clinical Emergency Hospital Bucharest (RO), Hôpital de Jolimont (BE)
Good health and well-being
Openalex Percentile: Top 25%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Successful Management of a Complex Coronary Bifurcation Lesion in Acute Coronary Syndrome Using a Free‐Metal Approach — Claudiu Ungureanu, Flavius‐Alexandru Gherasie · Catheterization and Cardiovascular Interventions (2026) | TGRS Research Map | TGRS