A tonic electrocutaneous stimulation paradigm for graded sensory C-fiber engagement in healthy subjects

Introduction Long-term pain models provide valuable proxies for studying physiological changes associated with chronic pain, which is commonly associated with sustained C-fiber-mediated nociceptive input and central sensitization, and are particularly useful in therapeutic and drug development research. We investigated tonic electrocutaneous stimulation (ECS), a method that enables precise temporal control and adjustable intensity within safe limits, using a 5 Hz sine-wave waveform intended to bias sensory responses toward C-fibers-mediated activity. Methods Twenty-one participants underwent three levels of personalized, 60-second ECS delivered at parameters intended to bias sensory responses toward C-fiber-mediated activity, three levels of short-term ECS using parameters commonly associated with Aδ-fiber-mediated responses, and mild long-term ECS using parameters commonly associated with Aβ-fiber-mediated activity as a non-painful control, skin conductance response (SCR) and level (SCL), continuous self-reported visual analog scale (VAS) pain ratings were recorded simultaneously. Results The low-, medium-, and high-intensity ECS conditions produced statistically distinct self-reported pain scores and differentiable sympathetic nervous system (SNS) activation patterns in SCR and SCL. Compared to the non-painful control, low-intensity C-fiber-biased ECS did not differ in pain perception or SNS activity, whereas medium and high intensities elicited significantly greater responses. Repeated-measures correlation analysis revealed very strong associations between VAS scores and stimulus intensity across the entire stimulation period ( r ≥ 0.90, p <.001). Both SCR and SCL exhibited fair correlation coefficients throughout stimulation ( r = 0.35-0.58, p <.05), while SCL correlations declined to poor, non-significant levels after first 30 seconds ( r = -0.05-0.22, p = n.s. ). Conclusion Our proposed model provides a controllable and reproducible approach for inducing long-term, intensity-dependent pain in human subjects, offering a physiologically relevant experimental paradigm with high temporal precision.

Authors

Institutions

Publication Details

Journal
Frontiers in Pain Research
Published
2026-03-12
DOI
https://doi.org/10.3389/fpain.2026.1779451
Primary Topic
Pain Mechanisms and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A tonic electrocutaneous stimulation paradigm for graded sensory C-fiber engagement in healthy subjects

Riley McNaboe, Andrew Peitzsch, Youngsun Kong, I-Ping Chen et al.
Frontiers in Pain Research
Pain Mechanisms and Treatments
article

A tonic electrocutaneous stimulation paradigm for graded sensory C-fiber engagement in healthy subjects

Riley McNaboe, Andrew Peitzsch, Youngsun Kong, I-Ping Chen, Ki H. Chon
article en

Abstract

Introduction Long-term pain models provide valuable proxies for studying physiological changes associated with chronic pain, which is commonly associated with sustained C-fiber-mediated nociceptive input and central sensitization, and are particularly useful in therapeutic and drug development research. We investigated tonic electrocutaneous stimulation (ECS), a method that enables precise temporal control and adjustable intensity within safe limits, using a 5 Hz sine-wave waveform intended to bias sensory responses toward C-fibers-mediated activity. Methods Twenty-one participants underwent three levels of personalized, 60-second ECS delivered at parameters intended to bias sensory responses toward C-fiber-mediated activity, three levels of short-term ECS using parameters commonly associated with Aδ-fiber-mediated responses, and mild long-term ECS using parameters commonly associated with Aβ-fiber-mediated activity as a non-painful control, skin conductance response (SCR) and level (SCL), continuous self-reported visual analog scale (VAS) pain ratings were recorded simultaneously. Results The low-, medium-, and high-intensity ECS conditions produced statistically distinct self-reported pain scores and differentiable sympathetic nervous system (SNS) activation patterns in SCR and SCL. Compared to the non-painful control, low-intensity C-fiber-biased ECS did not differ in pain perception or SNS activity, whereas medium and high intensities elicited significantly greater responses. Repeated-measures correlation analysis revealed very strong associations between VAS scores and stimulus intensity across the entire stimulation period ( r ≥ 0.90, p <.001). Both SCR and SCL exhibited fair correlation coefficients throughout stimulation ( r = 0.35-0.58, p <.05), while SCL correlations declined to poor, non-significant levels after first 30 seconds ( r = -0.05-0.22, p = n.s. ). Conclusion Our proposed model provides a controllable and reproducible approach for inducing long-term, intensity-dependent pain in human subjects, offering a physiologically relevant experimental paradigm with high temporal precision.

Frontiers in Pain ResearchVol. 7
University of Connecticut (US), American Association of Endodontists (US)
National Institutes of Health
Good health and well-being
Openalex Percentile: Top 23%
Pain Mechanisms and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.