Properties of Laser-Welded Zr-Al-Co-Nb Bulk Metallic Glass

In this study, the Nd:YAG laser process was employed with preselected welding parameters and varying initial welding temperatures (including room temperature, 10 °C, and 0 °C) for spot welding of (Zr<sub>53</sub>Al<sub>17</sub>Co<sub>29</sub>)Nb<sub>1</sub> bulk metallic glass. Following welding, the microstructure-including the parent material, heat-affected zone (HAZ), and weld fusion zone (WFZ)-as well as the microhardness, thermal properties, and corrosion resistance of the welds, were systematically investigated. Owing to the low glass-forming ability of the alloy, a small amount of Zr<sub>6</sub>CoAl<sub>2</sub> phase was observed within the amorphous matrix at the center of the bulk metallic glass cast plate. After the laser welding, sub-micron or nanoscale Zr(Al<sub>x</sub>Co<sub>1-x</sub>)<sub>2</sub> phases have formed in the HAZ of all welded samples, which significantly influenced the microhardness, thermal properties, and corrosion resistance in this region. As the initial welding temperature decreased, both the volume fraction and the density of the Zr(Al<sub>x</sub>Co<sub>1-x</sub>)<sub>2</sub> phase were reduced. Notably, for the weld performed at the lowest initial temperature of 0 °C, small crystalline phases were detected only at approximately 70 μm below the surface of the HAZ. To clarify the effect of IWTs on corrosion resistance, welded samples were immersed in 6 M HCl at 35 °C for 72-120 h. Surface morphologies after corrosion were examined by SEM in the PM, HAZ, and WFZ. No evident pitting was detected after 72 h of immersion. After 120 h, pitting corrosion was observed on the HAZ surfaces of welds subjected to RT and 10 °C IWTs, whereas no obvious pitting was found at an IWT of 0 °C. The pit size and density in the HAZ increased with increasing IWT. In contrast, no pitting was observed in the WFZ under any IWT condition.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-03-11
DOI
https://doi.org/10.3390/ma19061078
Primary Topic
Metallic Glasses and Amorphous Alloys
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Properties of Laser-Welded Zr-Al-Co-Nb Bulk Metallic Glass

Chih-Chun Hsieh, J.S.C. Jang, Kuo-Jung Lee, Hou-Guang Chen et al.
Materials
Metallic Glasses and Amorphous Alloys
article

Properties of Laser-Welded Zr-Al-Co-Nb Bulk Metallic Glass

Chih-Chun Hsieh, J.S.C. Jang, Kuo-Jung Lee, Hou-Guang Chen, Shao-Chi Wu, Huei-Sen Wang
article en

Abstract

In this study, the Nd:YAG laser process was employed with preselected welding parameters and varying initial welding temperatures (including room temperature, 10 °C, and 0 °C) for spot welding of (Zr<sub>53</sub>Al<sub>17</sub>Co<sub>29</sub>)Nb<sub>1</sub> bulk metallic glass. Following welding, the microstructure-including the parent material, heat-affected zone (HAZ), and weld fusion zone (WFZ)-as well as the microhardness, thermal properties, and corrosion resistance of the welds, were systematically investigated. Owing to the low glass-forming ability of the alloy, a small amount of Zr<sub>6</sub>CoAl<sub>2</sub> phase was observed within the amorphous matrix at the center of the bulk metallic glass cast plate. After the laser welding, sub-micron or nanoscale Zr(Al<sub>x</sub>Co<sub>1-x</sub>)<sub>2</sub> phases have formed in the HAZ of all welded samples, which significantly influenced the microhardness, thermal properties, and corrosion resistance in this region. As the initial welding temperature decreased, both the volume fraction and the density of the Zr(Al<sub>x</sub>Co<sub>1-x</sub>)<sub>2</sub> phase were reduced. Notably, for the weld performed at the lowest initial temperature of 0 °C, small crystalline phases were detected only at approximately 70 μm below the surface of the HAZ. To clarify the effect of IWTs on corrosion resistance, welded samples were immersed in 6 M HCl at 35 °C for 72-120 h. Surface morphologies after corrosion were examined by SEM in the PM, HAZ, and WFZ. No evident pitting was detected after 72 h of immersion. After 120 h, pitting corrosion was observed on the HAZ surfaces of welds subjected to RT and 10 °C IWTs, whereas no obvious pitting was found at an IWT of 0 °C. The pit size and density in the HAZ increased with increasing IWT. In contrast, no pitting was observed in the WFZ under any IWT condition.

MaterialsVol. 19(6)
National Central University (TW), I-Shou University (TW)
Openalex Percentile: Top 25%
Metallic Glasses and Amorphous Alloys
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.