Real-Time Probing of Biofouling Kinetics on Orthokeratology Lenses: QCM-D Quantification of Protein/Lipid Adsorption and Multipurpose Solution-Mediated Elution under Physiological Flow

Orthokeratology (OK) lenses for myopia correction are susceptible to biofouling by tear-derived biomolecules, escalating the risks of ocular infection and inflammation. Prevailing studies that rely on end point protein quantification fail to capture the real-time kinetics of fouling formation. Here, we fabricated a UV pressure-assisted polymer-grafted quartz crystal microbalance with dissipation monitoring (QCM-D) sensor exhibiting exceptional stability, nanoscale smoothness (RMS roughness ≈2 nm), and interfacial peel resistance. This platform enables in situ tracking of adsorption/desorption kinetics for four critical tear components: native/denatured lysozyme and oxidized/native lecithin. Key findings reveal a flow-dependent fouling behavior, wherein low flow rates increase biomolecule adsorption by 37-80% compared with higher flows. We further identify denatured lysozyme and native lecithin as resilient contaminants characterized by a stronger deposition affinity and pronounced resistance to elution. Quantitative screening of multipurpose solutions (MPSs) demonstrates that MPS #2 achieves 20-100% elution rate across biomolecules, outperforming commercial benchmarks. By leveraging dissipation-frequency (D-F) analysis, we clarify the fundamental mechanisms of biofouling formation at the molecular level. Collectively, this work establishes three critical advances: (1) a real-time biofouling diagnostic platform for OK lens interfaces, (2) molecular design principles for antifouling materials based on adhesion remodeling theory, and (3) an accelerated MPS formulation screening paradigm for ocular device safety.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2026-03-12
DOI
https://doi.org/10.1021/acs.langmuir.5c06272
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Probing of Biofouling Kinetics on Orthokeratology Lenses: QCM-D Quantification of Protein/Lipid Adsorption and Multipurpose Solution-Mediated Elution under Physiological Flow

C. Yan, L J Zhang, Qiang Zhang, Fang Cheng et al.
Langmuir
Ocular Surface and Contact Lens
article

Real-Time Probing of Biofouling Kinetics on Orthokeratology Lenses: QCM-D Quantification of Protein/Lipid Adsorption and Multipurpose Solution-Mediated Elution under Physiological Flow

C. Yan, L J Zhang, Qiang Zhang, Fang Cheng, Huan Tang, Jicheng Dong, Gang Cheng, Lin Jin, Weiye Liang, Yong Wang
article en

Abstract

Orthokeratology (OK) lenses for myopia correction are susceptible to biofouling by tear-derived biomolecules, escalating the risks of ocular infection and inflammation. Prevailing studies that rely on end point protein quantification fail to capture the real-time kinetics of fouling formation. Here, we fabricated a UV pressure-assisted polymer-grafted quartz crystal microbalance with dissipation monitoring (QCM-D) sensor exhibiting exceptional stability, nanoscale smoothness (RMS roughness ≈2 nm), and interfacial peel resistance. This platform enables in situ tracking of adsorption/desorption kinetics for four critical tear components: native/denatured lysozyme and oxidized/native lecithin. Key findings reveal a flow-dependent fouling behavior, wherein low flow rates increase biomolecule adsorption by 37-80% compared with higher flows. We further identify denatured lysozyme and native lecithin as resilient contaminants characterized by a stronger deposition affinity and pronounced resistance to elution. Quantitative screening of multipurpose solutions (MPSs) demonstrates that MPS #2 achieves 20-100% elution rate across biomolecules, outperforming commercial benchmarks. By leveraging dissipation-frequency (D-F) analysis, we clarify the fundamental mechanisms of biofouling formation at the molecular level. Collectively, this work establishes three critical advances: (1) a real-time biofouling diagnostic platform for OK lens interfaces, (2) molecular design principles for antifouling materials based on adhesion remodeling theory, and (3) an accelerated MPS formulation screening paradigm for ocular device safety.

LangmuirVol. 42(11)
Dalian University of Technology (CN), Westlake University (CN), Faculty (United Kingdom) (GB), The Third People's Hospital of Dalian City (CN), State Key Laboratory of Chemical Engineering (CN)
Openalex Percentile: Top 29%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.