Hydrogen gas sensing using platinum nanoparticles with nanogaps

In this study, we fabricated Pt nanoparticles with nanogaps on glass substrates and evaluated their electrical response to H2 gas. Pt nanoparticles with various gap sizes were exposed to H2 gas at 100 ppm, and we observed that a resistance change of 51.4% is achieved by optimizing the gap size. In conventional Pt nanostructure-based sensors, the H2 gas was detected through the resistance changes caused by electron scattering from H atoms adsorbed on the Pt surface or those diffused into grain boundaries and defects. The resistance change observed in this study was significantly larger than those observed in conventional sensors, and the above mechanism cannot fully explain the substantial resistance change. Consequently, our findings suggest that structural changes at the contact interfaces between nanoparticles contribute to the resistance change in Pt nanoparticles with nanogaps.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2026-03-11
DOI
https://doi.org/10.1063/5.0310670
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrogen gas sensing using platinum nanoparticles with nanogaps

Nobutomo Nakamura, Kanta Adachi, Reo Ura
Journal of Applied Physics
Gas Sensing Nanomaterials and Sensors
article

Hydrogen gas sensing using platinum nanoparticles with nanogaps

Nobutomo Nakamura, Kanta Adachi, Reo Ura
article en

Abstract

In this study, we fabricated Pt nanoparticles with nanogaps on glass substrates and evaluated their electrical response to H2 gas. Pt nanoparticles with various gap sizes were exposed to H2 gas at 100 ppm, and we observed that a resistance change of 51.4% is achieved by optimizing the gap size. In conventional Pt nanostructure-based sensors, the H2 gas was detected through the resistance changes caused by electron scattering from H atoms adsorbed on the Pt surface or those diffused into grain boundaries and defects. The resistance change observed in this study was significantly larger than those observed in conventional sensors, and the above mechanism cannot fully explain the substantial resistance change. Consequently, our findings suggest that structural changes at the contact interfaces between nanoparticles contribute to the resistance change in Pt nanoparticles with nanogaps.

Journal of Applied PhysicsVol. 139(10)
The University of Osaka (JP)
Openalex Percentile: Top 25%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.