A new multi-residue method for PFAS analysis in wastewater for environmental and public health risk assessment

This work focuses on the detection and quantification of per-/polyfluorinated alkyl substances (PFAS) in influent wastewater, using wastewater-based epidemiology via a new multi-residue ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. This covers a range of PFAS classes including perfluoroalkyl carboxylic acids (e.g. PFHxA), perfluoroalkyl sulfonic acids (e.g. PFBS), precursors (e.g. EtFOSAA), perfluoroalkyl phosphonic (e.g. PFOPA) and phosphinic acids (e.g. PFPiA), and novel PFAS (e.g. Gen X). Weak-anion exchange (WAX) cartridges and hydrophilic-lipophilic balance (HLB) solid-phase extraction cartridges for sample preparation were compared, with higher intensities and recoveries seen for different compounds for both cartridges. Method detection limits ranged from 0.03 (PFBS) to 756.9 ng L<sup>-1</sup> (MeFOSA). Average method accuracy was 95% with a precision of 17.9%. Elution solvents on HLB cartridges were tested (MeOH, ACN, and IPA), with MeOH found to work sufficiently for the analytes in this method. Some PFAS were found to adsorb to silanised glassware and HDPE material during sample preparation. The method was applied to influent wastewater samples from the South-West of England across three days to assess daily load and potential population exposure. Daily loads ranged from 1935.4 ± 146.9 (PFNA) to 45,368.9 ± 24,983.6 mg day<sup>-1</sup> (8:2 diPAP), and population-normalised daily load ranged from 2.5 ± 0.2 to 55.2 ± 30.4 µg day<sup>-1</sup> 1000 inh<sup>-1</sup> for those same compounds. Risk from human exposure and acute risk to the environment were assessed and deemed to be low; however, risk can be difficult to assess due to more factors needing to be considered.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-03-12
DOI
https://doi.org/10.1007/s00216-026-06421-5
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new multi-residue method for PFAS analysis in wastewater for environmental and public health risk assessment

Megan Robertson, John Bagnall, Harry Elliss, Dalia Elabbadi et al.
Analytical and Bioanalytical Chemistry
Per- and polyfluoroalkyl substances research
article

A new multi-residue method for PFAS analysis in wastewater for environmental and public health risk assessment

Megan Robertson, John Bagnall, Harry Elliss, Dalia Elabbadi, Barbara Kasprzyk-Hordern
article en

Abstract

This work focuses on the detection and quantification of per-/polyfluorinated alkyl substances (PFAS) in influent wastewater, using wastewater-based epidemiology via a new multi-residue ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. This covers a range of PFAS classes including perfluoroalkyl carboxylic acids (e.g. PFHxA), perfluoroalkyl sulfonic acids (e.g. PFBS), precursors (e.g. EtFOSAA), perfluoroalkyl phosphonic (e.g. PFOPA) and phosphinic acids (e.g. PFPiA), and novel PFAS (e.g. Gen X). Weak-anion exchange (WAX) cartridges and hydrophilic-lipophilic balance (HLB) solid-phase extraction cartridges for sample preparation were compared, with higher intensities and recoveries seen for different compounds for both cartridges. Method detection limits ranged from 0.03 (PFBS) to 756.9 ng L<sup>-1</sup> (MeFOSA). Average method accuracy was 95% with a precision of 17.9%. Elution solvents on HLB cartridges were tested (MeOH, ACN, and IPA), with MeOH found to work sufficiently for the analytes in this method. Some PFAS were found to adsorb to silanised glassware and HDPE material during sample preparation. The method was applied to influent wastewater samples from the South-West of England across three days to assess daily load and potential population exposure. Daily loads ranged from 1935.4 ± 146.9 (PFNA) to 45,368.9 ± 24,983.6 mg day<sup>-1</sup> (8:2 diPAP), and population-normalised daily load ranged from 2.5 ± 0.2 to 55.2 ± 30.4 µg day<sup>-1</sup> 1000 inh<sup>-1</sup> for those same compounds. Risk from human exposure and acute risk to the environment were assessed and deemed to be low; however, risk can be difficult to assess due to more factors needing to be considered.

Analytical and Bioanalytical Chemistry
University of Bath (GB)
Clean water and sanitation
Openalex Percentile: Top 33%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.