Technical feasibility of hyperbaric oxygen therapy for gas embolism with ECMO support: a brief report

Gas embolism (GE) occurs when gas enters into the circulation. Whilst small quantities of gas may be harmless, massive, or systemic GE may be life-threatening, when associated with coma, cardiogenic shock, or cardiac arrest. GE is a known complication of Extracorporeal Membrane Oxygenation (ECMO). Hyperbaric Oxygen Therapy (HBOT) is a corner-stone of GE management. Delivery of HBOT in patients supported by ECMO is an emerging area of interest. We aimed to assess the feasibility of using the Rotaflow I® (Maquet, Germany) ECMO device during HBOT, configured with mock circulatory loops (MCL) such that the pump head unit and oxygenator were located inside and the console external to the hyperbaric chamber. A control MCL was positioned outside the hyperbaric chamber with similar characteristics and parameters. Both oxygenators were alimented with oxygen sweep gas. Outflow stability was measured before, during and after a pressurization profile. Laboratory markers for hemolysis were assessed. Measurements were performed simultaneously on both MCL. ECMO outflow displayed on the console remained stable during hyperbaric pressurization profile. [maximum variation (delta max) of 0.16 L/min (3.1%) during HBOT versus 0.19 L/min (3.8%) at atmospheric pressure]. No significant variation was found between pre- and post-oxygenator pressure in the H-ECMO device (delta max 1 mmHg in pre- and post-oxygenator). Hemoglobin, haptoglobin and schistocytes concentrations remained stable. Conversely, measured plasma-free hemoglobin and LDH were increased temporarily during run in the device exposed to HBOT, then decreased when back at atmospheric pressure. These changes are likely related to technical issues. No relevant changes were observed in the control. Delivery of HBOT to patients with GE supported by ECMO seems technically feasible using a Rotaflow I® device with externalization of the console outside the hyperbaric chamber. No significant effect on performance or sustained effect on hemolysis were observed.

Authors

Institutions

Publication Details

Journal
Critical Care
Published
2026-03-12
DOI
https://doi.org/10.1186/s13054-026-05949-3
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical feasibility of hyperbaric oxygen therapy for gas embolism with ECMO support: a brief report

Adélaïde Hardeman, Julien Poissy, Erika Parmentier-Decrucq, Nicolas Dognon et al.
Critical Care
Mechanical Circulatory Support Devices
article

Technical feasibility of hyperbaric oxygen therapy for gas embolism with ECMO support: a brief report

Adélaïde Hardeman, Julien Poissy, Erika Parmentier-Decrucq, Nicolas Dognon, Mouhamed Djahoum Moussa, Anne‐Sophie Moreau, Benoît Brassart, Marie Jungling, Christine Djobo, Thibault Duburcq, Quentin Delforge, Valerie Soenen, Patrice Maboudou, Gaetan Legrand
article en

Abstract

Gas embolism (GE) occurs when gas enters into the circulation. Whilst small quantities of gas may be harmless, massive, or systemic GE may be life-threatening, when associated with coma, cardiogenic shock, or cardiac arrest. GE is a known complication of Extracorporeal Membrane Oxygenation (ECMO). Hyperbaric Oxygen Therapy (HBOT) is a corner-stone of GE management. Delivery of HBOT in patients supported by ECMO is an emerging area of interest. We aimed to assess the feasibility of using the Rotaflow I® (Maquet, Germany) ECMO device during HBOT, configured with mock circulatory loops (MCL) such that the pump head unit and oxygenator were located inside and the console external to the hyperbaric chamber. A control MCL was positioned outside the hyperbaric chamber with similar characteristics and parameters. Both oxygenators were alimented with oxygen sweep gas. Outflow stability was measured before, during and after a pressurization profile. Laboratory markers for hemolysis were assessed. Measurements were performed simultaneously on both MCL. ECMO outflow displayed on the console remained stable during hyperbaric pressurization profile. [maximum variation (delta max) of 0.16 L/min (3.1%) during HBOT versus 0.19 L/min (3.8%) at atmospheric pressure]. No significant variation was found between pre- and post-oxygenator pressure in the H-ECMO device (delta max 1 mmHg in pre- and post-oxygenator). Hemoglobin, haptoglobin and schistocytes concentrations remained stable. Conversely, measured plasma-free hemoglobin and LDH were increased temporarily during run in the device exposed to HBOT, then decreased when back at atmospheric pressure. These changes are likely related to technical issues. No relevant changes were observed in the control. Delivery of HBOT to patients with GE supported by ECMO seems technically feasible using a Rotaflow I® device with externalization of the console outside the hyperbaric chamber. No significant effect on performance or sustained effect on hemolysis were observed.

Critical Care
Centre Hospitalier Universitaire de Lille (FR)
Openalex Percentile: Top 26%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.