Evaluation of Pediatric Radiation Doses during Chest, Abdomen, and Babygram X-ray Examination Using GATE Code

One of the main concerns of radiography procedures is to produce diagnostic image quality with dose reduction, specifically for pediatric patients. In the present study, Monte Carlo simulations using GATE (Geant Application for Tomography Emission) code, coupled with a 7-wk-old voxel female baby model from the GSF (German Research Center for Environment Health) were performed to investigate how dose in digital chest, abdomen, and both chest and abdomen (babygram) x-ray examinations vary with tube voltage (40-60 keV) at a fixed value of current–time product (4 mAs) using different collimation and a digital radiography system. Organ dose (mGy) and effective doses (mSv) of three routine digital radiography examinations, namely anterior-posterior (AP) chest, anterior-posterior (AP) abdomen, and anterior-posterior (AP) chest-abdomen, were estimated using the Monte Carlo simulation method, GATE code. Organ doses ranged from 0.01 to a maximum of 2.5 mGy, while effective doses ranged from 0.01 to 0.3 mSv. The results of the present paper show that the organ doses and effective doses for chest, abdomen, and babygram x ray with digital radiography highlight no change, while increasing voltage and values obtained are still very low compared to similar references.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-03-12
DOI
https://doi.org/10.1097/hp.0000000000002143
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Pediatric Radiation Doses during Chest, Abdomen, and Babygram X-ray Examination Using GATE Code

M. Bougteb, M. Mkimel, Maroine Tahiri, Redouane El Baydaoui et al.
Health Physics
Radiation Dose and Imaging
article

Evaluation of Pediatric Radiation Doses during Chest, Abdomen, and Babygram X-ray Examination Using GATE Code

M. Bougteb, M. Mkimel, Maroine Tahiri, Redouane El Baydaoui, Noureddine Elamri
article en

Abstract

One of the main concerns of radiography procedures is to produce diagnostic image quality with dose reduction, specifically for pediatric patients. In the present study, Monte Carlo simulations using GATE (Geant Application for Tomography Emission) code, coupled with a 7-wk-old voxel female baby model from the GSF (German Research Center for Environment Health) were performed to investigate how dose in digital chest, abdomen, and both chest and abdomen (babygram) x-ray examinations vary with tube voltage (40-60 keV) at a fixed value of current–time product (4 mAs) using different collimation and a digital radiography system. Organ dose (mGy) and effective doses (mSv) of three routine digital radiography examinations, namely anterior-posterior (AP) chest, anterior-posterior (AP) abdomen, and anterior-posterior (AP) chest-abdomen, were estimated using the Monte Carlo simulation method, GATE code. Organ doses ranged from 0.01 to a maximum of 2.5 mGy, while effective doses ranged from 0.01 to 0.3 mSv. The results of the present paper show that the organ doses and effective doses for chest, abdomen, and babygram x ray with digital radiography highlight no change, while increasing voltage and values obtained are still very low compared to similar references.

Health Physics
Université Hassan 1er (MA)
Good health and well-being
Openalex Percentile: Top 27%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.