Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery

Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. <b>Methods:</b> We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with <sup>99m</sup>Tc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney <i>U</i> and Spearman correlation analyses. <b>Results:</b> Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (<i>P</i> = 0.11), and the median target scan duration decreased from 299 to 212 s (<i>P</i> = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, <i>P</i> = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (<i>P</i> = 0.08). <b>Conclusion:</b> Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine
Published
2026-03-12
DOI
https://doi.org/10.2967/jnumed.125.271693
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery

Berkay Alp Çakal, L. Zuur, Kateryna Pirkovets, Michiel Sinaasappel et al.
Journal of Nuclear Medicine
Advanced Radiotherapy Techniques
article

Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery

Berkay Alp Çakal, L. Zuur, Kateryna Pirkovets, Michiel Sinaasappel, Vera A. Ottens, Fijs W.B. van Leeuwen, Pim J. van Leeuwen, Henk G. van der Poel, Alberto Briganti, Giorgio Gandaglia
article en

Abstract

Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. <b>Methods:</b> We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with <sup>99m</sup>Tc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney <i>U</i> and Spearman correlation analyses. <b>Results:</b> Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (<i>P</i> = 0.11), and the median target scan duration decreased from 299 to 212 s (<i>P</i> = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, <i>P</i> = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (<i>P</i> = 0.08). <b>Conclusion:</b> Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.

Journal of Nuclear Medicine
Vita-Salute San Raffaele University (IT), University of Augsburg (DE), Leiden University Medical Center (NL), University Hospital Augsburg (DE), The Netherlands Cancer Institute (NL), Holoeye Photonics (Germany) (DE), IRCCS Ospedale San Raffaele (IT)
Openalex Percentile: Top 22%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.