Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery
Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. <b>Methods:</b> We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with <sup>99m</sup>Tc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney <i>U</i> and Spearman correlation analyses. <b>Results:</b> Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (<i>P</i> = 0.11), and the median target scan duration decreased from 299 to 212 s (<i>P</i> = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, <i>P</i> = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (<i>P</i> = 0.08). <b>Conclusion:</b> Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.
Authors
- Berkay Alp Çakal (ORCID: https://orcid.org/0009-0009-2807-1103)
- L. Zuur (ORCID: https://orcid.org/0009-0000-7392-1626)
- Kateryna Pirkovets (ORCID: https://orcid.org/0009-0001-7523-5387)
- Michiel Sinaasappel
- Vera A. Ottens (ORCID: https://orcid.org/0009-0001-1791-201X)
- Fijs W.B. van Leeuwen
- Pim J. van Leeuwen
- Henk G. van der Poel
- Alberto Briganti
- Giorgio Gandaglia
Institutions
- Vita-Salute San Raffaele University (IT)
- University of Augsburg (DE)
- Leiden University Medical Center (NL)
- University Hospital Augsburg (DE)
- The Netherlands Cancer Institute (NL)
- Holoeye Photonics (Germany) (DE)
- IRCCS Ospedale San Raffaele (IT)
Publication Details
- Journal
- Journal of Nuclear Medicine
- Published
- 2026-03-12
- DOI
- https://doi.org/10.2967/jnumed.125.271693
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00