Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising

Purpose: Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare’s AIR-Recon DLTM (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to patch-based MPPCASVS and NORDIC denoising methods on high-resolution dMRI data.Methods: We developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCASVS, NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the signal profiles in highly anisotropic areas, and secondary downstream measurements, such as fiber orientation estimation and white matter tractography.Results: Our validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL.Conclusion: We found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCASVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution and reduction of noise variance.

Publication Details

Journal
Repository@Nottingham (University of Nottingham)
Published
2026-03-07
DOI
https://doi.org/10.1002/mrm.70336digital+object+identifier+%28doi%29
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising

Repository@Nottingham (University of Nottingham)
Advanced Neuroimaging Techniques and Applications
article

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising

article en

Abstract

Purpose: Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare’s AIR-Recon DLTM (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to patch-based MPPCASVS and NORDIC denoising methods on high-resolution dMRI data.Methods: We developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCASVS, NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the signal profiles in highly anisotropic areas, and secondary downstream measurements, such as fiber orientation estimation and white matter tractography.Results: Our validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL.Conclusion: We found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCASVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution and reduction of noise variance.

Repository@Nottingham (University of Nottingham)
Industry, innovation and infrastructure
Openalex Percentile: Top 27%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising · Repository@Nottingham (University of Nottingham) (2026) | TGRS Research Map | TGRS