Multi-source harmonic estimation method for distribution networks based on variational modal decomposition

To address the limitation of harmonic monitoring on the low-voltage side of distribution networks, this paper proposes a multi-source harmonic estimation method based on variational mode decomposition. The method integrates short-term test data with long-term power data. First, dominant harmonic users are identified through a strategy that combines Fisher optimal segmentation and derivative dynamic time warping. Second, an electrical data transformation approach is designed by combining variational mode decomposition with Gramian angular fields, which maps the power signals of dominant harmonic users and low-voltage side harmonic signals into pseudo-color Gramian power images and grayscale Gramian harmonic images, respectively. Finally, an improved PSRGAN (pix2pix-super-resolution generative adversarial network) model is constructed to train and learn from these images, establishing the mapping relationship between power data and low-voltage side harmonic data of the distribution network, thereby enabling the migration and generation of long-term low-voltage side harmonic monitoring data. Simulation cases and field measurements validate the effectiveness and accuracy of the proposed method in multi-source harmonic scenarios. Moreover, the required data are easily accessible, demonstrating strong potential for engineering applications.

Authors

Publication Details

Journal
PLoS ONE
Published
2026-03-11
DOI
https://doi.org/10.1371/journal.pone.0341910
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-source harmonic estimation method for distribution networks based on variational modal decomposition

Hongyan Xu, Zeping Yu, Hongjian Zuo, Zekun Wang et al.
PLoS ONE
Power Quality and Harmonics
article

Multi-source harmonic estimation method for distribution networks based on variational modal decomposition

Hongyan Xu, Zeping Yu, Hongjian Zuo, Zekun Wang, Zhiqiang Wu
article en

Abstract

To address the limitation of harmonic monitoring on the low-voltage side of distribution networks, this paper proposes a multi-source harmonic estimation method based on variational mode decomposition. The method integrates short-term test data with long-term power data. First, dominant harmonic users are identified through a strategy that combines Fisher optimal segmentation and derivative dynamic time warping. Second, an electrical data transformation approach is designed by combining variational mode decomposition with Gramian angular fields, which maps the power signals of dominant harmonic users and low-voltage side harmonic signals into pseudo-color Gramian power images and grayscale Gramian harmonic images, respectively. Finally, an improved PSRGAN (pix2pix-super-resolution generative adversarial network) model is constructed to train and learn from these images, establishing the mapping relationship between power data and low-voltage side harmonic data of the distribution network, thereby enabling the migration and generation of long-term low-voltage side harmonic monitoring data. Simulation cases and field measurements validate the effectiveness and accuracy of the proposed method in multi-source harmonic scenarios. Moreover, the required data are easily accessible, demonstrating strong potential for engineering applications.

PLoS ONEVol. 21(3)
Openalex Percentile: Top 26%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.