Comparison of monocular video-based methods for measuring the amplitude of hand tremor

Accurate assessment of hand tremor is critical to help diagnose and monitor multiple neurological conditions. In routine practice, clinicians subjectively estimate tremor frequency and amplitude, but this has poor reliability. Recently, objective methods for assessing hand tremor using computer vision approaches have been proposed. This work compares the accuracy of three such approaches. Tremor amplitude, in pixels, is first estimated from smartphone videos by extracting a pose skeleton and then estimating the extreme points of motion. Conversion to metric amplitude requires scene-depth information. Three approaches are investigated: (a) on-device LiDAR (b) deep-learning prediction and (c) a non-dimensional estimate of amplitude, normalising against the size of the hand. 120 videos of hands simulating rest, postural, and kinetic tremor were recorded from 20 healthy participants. Gold-standard measurements of amplitude were obtained using a within-scene ruler. We conducted Bland-Altman analysis for each approach, where bias was calculated as gold-standard - estimate. In sub-group analysis, we reported results for each tremor test and by skin tone. The bias was -0.01 cm (95% limits of agreement = ±0.78 cm) using method (a). The bias was -0.91 cm (95% limits of agreement of ±1.88 cm) for method (b). There was no statistically significant difference in amplitude accuracy, depending on skin colour as assessed using the Monk Skin Tone scale (p=0.32). Method (c) was highly correlated (r=0.977) with the gold-standard. In conclusion, depth estimates from a state-of-the-art neural network are too inaccurate for quantifying hand tremor amplitude. In contrast, LiDAR depth measurements allow hand tremor amplitude to be estimated accurately for simulated tremor.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2026-03-11
DOI
https://doi.org/10.1016/j.compbiomed.2026.111615
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of monocular video-based methods for measuring the amplitude of hand tremor

David Wong, Stefan B. Williams, Samuel D. Relton, Valeria Filippou et al.
Computers in Biology and Medicine
Neurological disorders and treatments
article

Comparison of monocular video-based methods for measuring the amplitude of hand tremor

David Wong, Stefan B. Williams, Samuel D. Relton, Valeria Filippou, J. Alty, Katherine Bliss
article en

Abstract

Accurate assessment of hand tremor is critical to help diagnose and monitor multiple neurological conditions. In routine practice, clinicians subjectively estimate tremor frequency and amplitude, but this has poor reliability. Recently, objective methods for assessing hand tremor using computer vision approaches have been proposed. This work compares the accuracy of three such approaches. Tremor amplitude, in pixels, is first estimated from smartphone videos by extracting a pose skeleton and then estimating the extreme points of motion. Conversion to metric amplitude requires scene-depth information. Three approaches are investigated: (a) on-device LiDAR (b) deep-learning prediction and (c) a non-dimensional estimate of amplitude, normalising against the size of the hand. 120 videos of hands simulating rest, postural, and kinetic tremor were recorded from 20 healthy participants. Gold-standard measurements of amplitude were obtained using a within-scene ruler. We conducted Bland-Altman analysis for each approach, where bias was calculated as gold-standard - estimate. In sub-group analysis, we reported results for each tremor test and by skin tone. The bias was -0.01 cm (95% limits of agreement = ±0.78 cm) using method (a). The bias was -0.91 cm (95% limits of agreement of ±1.88 cm) for method (b). There was no statistically significant difference in amplitude accuracy, depending on skin colour as assessed using the Monk Skin Tone scale (p=0.32). Method (c) was highly correlated (r=0.977) with the gold-standard. In conclusion, depth estimates from a state-of-the-art neural network are too inaccurate for quantifying hand tremor amplitude. In contrast, LiDAR depth measurements allow hand tremor amplitude to be estimated accurately for simulated tremor.

Computers in Biology and MedicineVol. 206
University of Tasmania (AU), University of Leeds (GB), Leeds Teaching Hospitals NHS Trust (GB), Leeds College of Building (GB), University of Portsmouth (GB)
Openalex Percentile: Top 33%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.