SafeCREW Policy Brief #3 Managing the transition from non-disinfected to disinfected drinking water supply systems

Based on SafeCREW’s main findings, this policy brief provides evidence-based guidance for transitioning to disinfected drinking water networks, supporting decision makers and utilities in managing DBPs in water treatment and distribution systems. Recommendations for disinfection If the water distribuon network is well-maintained, UV disinfecon is highly recommended. The selection of disinfectants depends on source water and network conditions. Sodium hypochlorite (NaOCl) or chlorine dioxide (ClO₂) are generally recommended, while chloramine may be preferred in certain cases. For ClO₂, on-site generation, cold storage, and frequent monitoring of chlorite and chlorate are required, avoiding long-term storage. For NaOCl, storage time and temperature must be optimized to prevent chlorate formation considering site-specific factors. Disinfectant dosing should be kept at the minimum required to maintain microbial water safety. Advanced monitoring and automated dosing systems help achieve precise control, reducing the formation of regulated disinfection by-products (DBPs). Water utilities should implement or optimize treatment technologies, such as coagulation/flocculation, ozonation, activated carbon, or selective membrane adsorption, to selectively remove natural organic matter (NOM) that serves as precursor for regulated DBPs. Water utilities should use predictive or metamodel-based systems to optimize disinfectant dosing and minimize DBPs.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-28
DOI
https://doi.org/10.5281/zenodo.18852788
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SafeCREW Policy Brief #3 Managing the transition from non-disinfected to disinfected drinking water supply systems

Mathias Ernst, Manuela Antonelli, Andreu Fargas-Marquès, Irene Jubany et al.
Zenodo (CERN European Organization for Nuclear Research)
Water Treatment and Disinfection
article

SafeCREW Policy Brief #3 Managing the transition from non-disinfected to disinfected drinking water supply systems

Mathias Ernst, Manuela Antonelli, Andreu Fargas-Marquès, Irene Jubany, Serhii Martynov, Cynthia Kalweit
article en

Abstract

Based on SafeCREW’s main findings, this policy brief provides evidence-based guidance for transitioning to disinfected drinking water networks, supporting decision makers and utilities in managing DBPs in water treatment and distribution systems. Recommendations for disinfection If the water distribuon network is well-maintained, UV disinfecon is highly recommended. The selection of disinfectants depends on source water and network conditions. Sodium hypochlorite (NaOCl) or chlorine dioxide (ClO₂) are generally recommended, while chloramine may be preferred in certain cases. For ClO₂, on-site generation, cold storage, and frequent monitoring of chlorite and chlorate are required, avoiding long-term storage. For NaOCl, storage time and temperature must be optimized to prevent chlorate formation considering site-specific factors. Disinfectant dosing should be kept at the minimum required to maintain microbial water safety. Advanced monitoring and automated dosing systems help achieve precise control, reducing the formation of regulated disinfection by-products (DBPs). Water utilities should implement or optimize treatment technologies, such as coagulation/flocculation, ozonation, activated carbon, or selective membrane adsorption, to selectively remove natural organic matter (NOM) that serves as precursor for regulated DBPs. Water utilities should use predictive or metamodel-based systems to optimize disinfectant dosing and minimize DBPs.

Zenodo (CERN European Organization for Nuclear Research)
Universität Hamburg (DE), Fundació CTM Centre Tecnològic (ES), German Environment Agency (DE), Barcelona Media (ES), Consorci Sanitari Garraf (ES), Hamburg University of Technology (DE), Politecnico di Milano (IT)
Clean water and sanitation
Openalex Percentile: Top 33%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.