Feasibility and outcomes of single-incision robotic nipple-sparing mastectomy: a systematic review and meta-analysis

Single-incision robotic nipple-sparing mastectomy (RNSM) is an emerging minimally invasive approach for breast cancer and prophylactic surgery, yet its safety and feasibility remain to be confirmed. We conducted a comprehensive systematic review and meta-analysis to examine the single-incision RNSM perioperative parameters and complications. A bibliographic search was conducted according to the PRISMA guidelines across four databases. Following deduplication and exclusion, thirteen studies were eligible and constituted this study. Data were combined using random-effects models. Forest plots were generated to estimate pooled proportions using the Freeman-Tukey double arcsine transformation, and heterogeneity was assessed via I2 statistics. Quality assessment was performed using the Joanna Briggs Institute Checklist for Prevalence Studies. Funnel plots were used to assess publication bias. This study was registered on the PROSPERO registry. The pooled mean operative time was 273 min, and the mean blood loss was 82 ml. Pooled complication rates were relatively low, including skin-flap necrosis (2.4%), nipple-areolar complex necrosis (0.4%), delayed wound healing (4.7%), surgical-site infection (3.8%), deep infection (1.2%), hematoma (2.4%), and seroma (5.8%). Pooled estimate of positive margin rate was < 1%. Locoregional and distant recurrence rates were 0.8% and 0.4%, respectively. No conversions to open surgery or procedure-related deaths were reported. The single-incision RNSM is a modern surgical approach with acceptable perioperative parameters and satisfactory complication rates. However, heterogeneity across studies and the relative rarity of long-term oncological data warranted cautious interpretation. Prospective comparative trials are necessary to prove the oncological safety and economic effectiveness compared with other approaches.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-03-11
DOI
https://doi.org/10.1007/s11701-026-03297-6
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and outcomes of single-incision robotic nipple-sparing mastectomy: a systematic review and meta-analysis

Hasan Asfour, Ewa Anna Sobczak, Hussein Lubbad, Walid Sasi
Journal of Robotic Surgery
Breast Implant and Reconstruction
article

Feasibility and outcomes of single-incision robotic nipple-sparing mastectomy: a systematic review and meta-analysis

Hasan Asfour, Ewa Anna Sobczak, Hussein Lubbad, Walid Sasi
article en

Abstract

Single-incision robotic nipple-sparing mastectomy (RNSM) is an emerging minimally invasive approach for breast cancer and prophylactic surgery, yet its safety and feasibility remain to be confirmed. We conducted a comprehensive systematic review and meta-analysis to examine the single-incision RNSM perioperative parameters and complications. A bibliographic search was conducted according to the PRISMA guidelines across four databases. Following deduplication and exclusion, thirteen studies were eligible and constituted this study. Data were combined using random-effects models. Forest plots were generated to estimate pooled proportions using the Freeman-Tukey double arcsine transformation, and heterogeneity was assessed via I2 statistics. Quality assessment was performed using the Joanna Briggs Institute Checklist for Prevalence Studies. Funnel plots were used to assess publication bias. This study was registered on the PROSPERO registry. The pooled mean operative time was 273 min, and the mean blood loss was 82 ml. Pooled complication rates were relatively low, including skin-flap necrosis (2.4%), nipple-areolar complex necrosis (0.4%), delayed wound healing (4.7%), surgical-site infection (3.8%), deep infection (1.2%), hematoma (2.4%), and seroma (5.8%). Pooled estimate of positive margin rate was < 1%. Locoregional and distant recurrence rates were 0.8% and 0.4%, respectively. No conversions to open surgery or procedure-related deaths were reported. The single-incision RNSM is a modern surgical approach with acceptable perioperative parameters and satisfactory complication rates. However, heterogeneity across studies and the relative rarity of long-term oncological data warranted cautious interpretation. Prospective comparative trials are necessary to prove the oncological safety and economic effectiveness compared with other approaches.

Journal of Robotic SurgeryVol. 20(1)
University of Leicester (GB), Leicester Royal Infirmary (GB), Wrightington, Wigan and Leigh NHS Foundation Trust (GB), University Hospitals of Leicester NHS Trust (GB)
Zero hunger
Openalex Percentile: Top 26%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.