A non-convex variational model for joint polyenergetic ct reconstruction, sensor denoising and material decomposition

Computed Tomography (CT) is widely used in engineering and medicine for imaging the interior of objects, patients, or animals. If the employed X-ray source is monoenergetic, image reconstruction essentially means the inversion of a ray transform. Typical X-ray sources are however polyenergetic (i.e. emit multiple wavelengths, each with different attenuation behaviour), and ignoring this fact may lead to artefacts such as beam hardening. An additional difficulty in some settings represents the occurrence of two different types of noise, the photon counting effect on the detector and the electronic noise generated e.g. by CCD cameras. We propose a novel variational image reconstruction model that takes both noise types and the polyenergetic source into account and moreover decomposes the reconstruction into different materials based on their different attenuation behaviour. In addition to a detailed mathematical analysis of the model we put forward a corresponding iterative algorithm including its convergence analysis. Numerical reconstructions of phantom data illustrate the feasibility of the approach.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-04-17
DOI
https://doi.org/10.1051/m2an/2026023/pdf
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A non-convex variational model for joint polyenergetic ct reconstruction, sensor denoising and material decomposition

Benedikt Wirth, Georgios Papanikos
Springer Link (Chiba Institute of Technology)
Medical Imaging Techniques and Applications
article

A non-convex variational model for joint polyenergetic ct reconstruction, sensor denoising and material decomposition

Benedikt Wirth, Georgios Papanikos
article en

Abstract

Computed Tomography (CT) is widely used in engineering and medicine for imaging the interior of objects, patients, or animals. If the employed X-ray source is monoenergetic, image reconstruction essentially means the inversion of a ray transform. Typical X-ray sources are however polyenergetic (i.e. emit multiple wavelengths, each with different attenuation behaviour), and ignoring this fact may lead to artefacts such as beam hardening. An additional difficulty in some settings represents the occurrence of two different types of noise, the photon counting effect on the detector and the electronic noise generated e.g. by CCD cameras. We propose a novel variational image reconstruction model that takes both noise types and the polyenergetic source into account and moreover decomposes the reconstruction into different materials based on their different attenuation behaviour. In addition to a detailed mathematical analysis of the model we put forward a corresponding iterative algorithm including its convergence analysis. Numerical reconstructions of phantom data illustrate the feasibility of the approach.

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 56%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.