Frequency–Direction Coupling in the Glass Transition Response of Thermally Aged Wet-Layup Unidirectional Carbon/Epoxy Composites

Dynamic mechanical thermal analysis (DMTA) is widely used to assess the effects of process- and environment-induced changes in polymer matrix composites, with the glass transition temperature (T<sub>g</sub>) often reported from the tan d peak at a single excitation frequency. However, such an approach neglects the inherently kinetic nature of the glass transition and may obscure thermally induced changes in relaxation response. Multi-frequency DMTA was employed to investigate the evolution of glass transition response of a wet-layup unidirectional carbon/epoxy composite subjected to thermal aging at temperatures ranging from 66 °C to 260 °C for periods up to 72 h, using unexposed (23 °C) results as an ambient baseline reference. Tests were conducted using a single cantilever mode in both longitudinal and transverse configurations over a range of excitation frequencies from 0.3 to 30 Hz. Results demonstrate that thermal exposure affects not only the absolute value of the glass transition temperature, but also its frequency sensitivity and directional dependence. A frequency sensitivity parameter and a directional amplification factor are introduced to quantify frequency-direction coupling. While post-cure-dominated aging regimes exhibit relatively stable coupling behavior, degradation-dominated conditions at elevated temperatures and longer periods of thermal exposure lead to pronounced increases in transverse frequency sensitivity, which reflects early evolution of matrix- and interphase-level deterioration. These findings highlight the value of multi-frequency DMTA with tests in both primary directions for the mechanistic assessment of effects of thermo-oxidative response in polymer matrix composites.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-03-11
DOI
https://doi.org/10.3390/polym18060680
Primary Topic
Mechanical Behavior of Composites
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency–Direction Coupling in the Glass Transition Response of Thermally Aged Wet-Layup Unidirectional Carbon/Epoxy Composites

Rabina Acharya, Vistasp M. Karbhari, Kruthika Kokku
Polymers
Mechanical Behavior of Composites
article

Frequency–Direction Coupling in the Glass Transition Response of Thermally Aged Wet-Layup Unidirectional Carbon/Epoxy Composites

Rabina Acharya, Vistasp M. Karbhari, Kruthika Kokku
article en

Abstract

Dynamic mechanical thermal analysis (DMTA) is widely used to assess the effects of process- and environment-induced changes in polymer matrix composites, with the glass transition temperature (T<sub>g</sub>) often reported from the tan d peak at a single excitation frequency. However, such an approach neglects the inherently kinetic nature of the glass transition and may obscure thermally induced changes in relaxation response. Multi-frequency DMTA was employed to investigate the evolution of glass transition response of a wet-layup unidirectional carbon/epoxy composite subjected to thermal aging at temperatures ranging from 66 °C to 260 °C for periods up to 72 h, using unexposed (23 °C) results as an ambient baseline reference. Tests were conducted using a single cantilever mode in both longitudinal and transverse configurations over a range of excitation frequencies from 0.3 to 30 Hz. Results demonstrate that thermal exposure affects not only the absolute value of the glass transition temperature, but also its frequency sensitivity and directional dependence. A frequency sensitivity parameter and a directional amplification factor are introduced to quantify frequency-direction coupling. While post-cure-dominated aging regimes exhibit relatively stable coupling behavior, degradation-dominated conditions at elevated temperatures and longer periods of thermal exposure lead to pronounced increases in transverse frequency sensitivity, which reflects early evolution of matrix- and interphase-level deterioration. These findings highlight the value of multi-frequency DMTA with tests in both primary directions for the mechanistic assessment of effects of thermo-oxidative response in polymer matrix composites.

PolymersVol. 18(6)
The University of Texas at Arlington (US)
Openalex Percentile: Top 28%
Mechanical Behavior of Composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.