Grid-related protection for distributed energy resource balancing voltage and frequency ride-through capabilities with rapid fault isolation

As the penetration rate of distributed energy resources (DERs) in distribution grids continues to increase, their voltage and frequency support capabilities during system disturbances and grid faults become increasingly critical, necessitating compliance with low-voltage ride-through (LVRT) standards. However, this requirement conflicts with the need for DERs to be selectively and rapidly shed during grid faults and islanding operations. To address this issue, this study proposes a grid-related protection scheme for DERs that balances the enhancement of grid frequency and voltage support capabilities with rapid fault isolation. First, based on meeting the LVRT standards and anti-islanding protection requirements for DERs, and considering the impact of DERs on system security and reclosing during grid faults, we propose differentiated grid-related protection operation requirements for scenarios including system disturbances, islanding operation, and grid faults. Second, the scheme refines operational scenarios, analyzes electrical quantity differences at DER grid connection points, and extracts key characteristic threshold values to distinguish different operational states. Finally, a multi-criteria grid protection scheme based on the voltage change rate is proposed, integrating characteristic indicators such as the rate of change of frequency (RoCoF), frequency, and voltage, along with differentiated action time. Theoretical analysis and simulation results demonstrate that this approach ensures rapid and selective disconnection of DERs affecting system security and reclosing during system faults or islanding operations while simultaneously preserving the grid’s frequency and voltage enhancement capabilities. This achieves a balanced integration of DERs within the system’s disturbance ride-through capability, anti-islanding protection, and fault protection capabilities.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2026-03-11
DOI
https://doi.org/10.3389/fenrg.2026.1780190
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid-related protection for distributed energy resource balancing voltage and frequency ride-through capabilities with rapid fault isolation

Shuxian Fan, Hechong Chen, Bingyin Xu, Zhichun Yang et al.
Frontiers in Energy Research
Islanding Detection in Power Systems
article

Grid-related protection for distributed energy resource balancing voltage and frequency ride-through capabilities with rapid fault isolation

Shuxian Fan, Hechong Chen, Bingyin Xu, Zhichun Yang, Fan Yang, Bei Meng, Yang Lei
article en

Abstract

As the penetration rate of distributed energy resources (DERs) in distribution grids continues to increase, their voltage and frequency support capabilities during system disturbances and grid faults become increasingly critical, necessitating compliance with low-voltage ride-through (LVRT) standards. However, this requirement conflicts with the need for DERs to be selectively and rapidly shed during grid faults and islanding operations. To address this issue, this study proposes a grid-related protection scheme for DERs that balances the enhancement of grid frequency and voltage support capabilities with rapid fault isolation. First, based on meeting the LVRT standards and anti-islanding protection requirements for DERs, and considering the impact of DERs on system security and reclosing during grid faults, we propose differentiated grid-related protection operation requirements for scenarios including system disturbances, islanding operation, and grid faults. Second, the scheme refines operational scenarios, analyzes electrical quantity differences at DER grid connection points, and extracts key characteristic threshold values to distinguish different operational states. Finally, a multi-criteria grid protection scheme based on the voltage change rate is proposed, integrating characteristic indicators such as the rate of change of frequency (RoCoF), frequency, and voltage, along with differentiated action time. Theoretical analysis and simulation results demonstrate that this approach ensures rapid and selective disconnection of DERs affecting system security and reclosing during system faults or islanding operations while simultaneously preserving the grid’s frequency and voltage enhancement capabilities. This achieves a balanced integration of DERs within the system’s disturbance ride-through capability, anti-islanding protection, and fault protection capabilities.

Frontiers in Energy ResearchVol. 14
Kema International (Netherlands) (NL), Shandong University of Science and Technology (CN)
State Grid Corporation of China
Openalex Percentile: Top 27%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.