Cost-Effective and Drift-Resistant Fiber-Optic Ultrasound Detection with Slope-Symmetric Fabry–Perot Sensor and AOM-Enabled Quadrature Demodulation

A robust and cost-effective fiber-optic ultrasound sensor based on a slope-symmetric Fabry–Perot interferometer (FPI) is presented, employing dual-channel quadrature-biased heterodyne interrogation with an acousto-optic modulator (AOM). By introducing a 200 MHz frequency shift that yields an effective π/2 phase offset between the direct (unshifted) and frequency-shifted optical paths, the system ensures complementary sensitivity: when one channel operates at zero slope on the FPI transfer function (minimum sensitivity), the other resides at maximum slope, providing inherent immunity to laser wavelength drift and environmental perturbations. Experimental validation demonstrates reliable ultrasound detection across varying operating points. At quadrature extremes, one channel achieves peak amplitudes of ±2 V while the other is quiescent, whereas intermediate points enable simultaneous detection with amplitudes of ±1.5 V (AOM channel) and ±0.05–0.1 V (direct channel), accompanied by corresponding DC levels ranging from ~0.4 V to 1.6 V. The AOM channel utilizes simple envelope detection after 9.5–11.5 MHz bandpass filtering, maintaining low cost, though coherent mixing is suggested for enhanced weak-signal performance. The angle-symmetric FPI design, combined with gold-disk reflector adaptations and potential femtosecond laser micromachining, further reduces fabrication costs without sacrificing finesse or sensitivity. This quadrature-biased approach offers superior stability compared to single-channel systems, making it highly suitable for practical applications in photoacoustic imaging, nondestructive testing, and structural health monitoring.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2026-03-11
DOI
https://doi.org/10.3390/photonics13030267
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cost-Effective and Drift-Resistant Fiber-Optic Ultrasound Detection with Slope-Symmetric Fabry–Perot Sensor and AOM-Enabled Quadrature Demodulation

Y. N. Wang, Mohammed Alshammari, Yufei Chu, Zi Li et al.
Photonics
Photoacoustic and Ultrasonic Imaging
article

Cost-Effective and Drift-Resistant Fiber-Optic Ultrasound Detection with Slope-Symmetric Fabry–Perot Sensor and AOM-Enabled Quadrature Demodulation

Y. N. Wang, Mohammed Alshammari, Yufei Chu, Zi Li, Ming Han
article en

Abstract

A robust and cost-effective fiber-optic ultrasound sensor based on a slope-symmetric Fabry–Perot interferometer (FPI) is presented, employing dual-channel quadrature-biased heterodyne interrogation with an acousto-optic modulator (AOM). By introducing a 200 MHz frequency shift that yields an effective π/2 phase offset between the direct (unshifted) and frequency-shifted optical paths, the system ensures complementary sensitivity: when one channel operates at zero slope on the FPI transfer function (minimum sensitivity), the other resides at maximum slope, providing inherent immunity to laser wavelength drift and environmental perturbations. Experimental validation demonstrates reliable ultrasound detection across varying operating points. At quadrature extremes, one channel achieves peak amplitudes of ±2 V while the other is quiescent, whereas intermediate points enable simultaneous detection with amplitudes of ±1.5 V (AOM channel) and ±0.05–0.1 V (direct channel), accompanied by corresponding DC levels ranging from ~0.4 V to 1.6 V. The AOM channel utilizes simple envelope detection after 9.5–11.5 MHz bandpass filtering, maintaining low cost, though coherent mixing is suggested for enhanced weak-signal performance. The angle-symmetric FPI design, combined with gold-disk reflector adaptations and potential femtosecond laser micromachining, further reduces fabrication costs without sacrificing finesse or sensitivity. This quadrature-biased approach offers superior stability compared to single-channel systems, making it highly suitable for practical applications in photoacoustic imaging, nondestructive testing, and structural health monitoring.

PhotonicsVol. 13(3)
Alma College (US), University of Michigan (US), Michigan State University (US)
Office of Naval Research
Openalex Percentile: Top 28%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.