2D-RIXS: resonant inelastic X-ray scattering microscopy with high energy and spatial resolutions

A two-dimensional resonant inelastic X-ray scattering (2D-RIXS) microscopy system has been developed at beamline BL02U of NanoTerasu. The instrument combines a Wolter type-I mirror for spatial imaging with a varied-line-spacing grating spectrometer, simultaneously achieving micrometre-scale spatial resolution and ultrahigh energy resolution in the soft X-ray regime. Test chart measurements confirm a vertical spatial resolution of 1.0 µm near the field-of-view center, and the horizontal resolution determined by the incident beam footprint is 0.8 µm. RIXS imaging capabilities have been demonstrated by the measurements of a patterned NanoTerasu logo and exfoliated NiPS<sub>3</sub> nanoflakes, highlighting its efficiency in locating specific microscale regions within inhomogeneous samples. These results establish 2D-RIXS microscopy as a position-sensitive probe of elementary excitations in quantum materials and functional devices.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2026-02-02
DOI
https://doi.org/10.1107/s1600577526000573
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2D-RIXS: resonant inelastic X-ray scattering microscopy with high energy and spatial resolutions

H. Suzuki, Jun Miyawaki, K. Yamamoto
Journal of Synchrotron Radiation
Advanced X-ray Imaging Techniques
article

2D-RIXS: resonant inelastic X-ray scattering microscopy with high energy and spatial resolutions

H. Suzuki, Jun Miyawaki, K. Yamamoto
article en

Abstract

A two-dimensional resonant inelastic X-ray scattering (2D-RIXS) microscopy system has been developed at beamline BL02U of NanoTerasu. The instrument combines a Wolter type-I mirror for spatial imaging with a varied-line-spacing grating spectrometer, simultaneously achieving micrometre-scale spatial resolution and ultrahigh energy resolution in the soft X-ray regime. Test chart measurements confirm a vertical spatial resolution of 1.0 µm near the field-of-view center, and the horizontal resolution determined by the incident beam footprint is 0.8 µm. RIXS imaging capabilities have been demonstrated by the measurements of a patterned NanoTerasu logo and exfoliated NiPS<sub>3</sub> nanoflakes, highlighting its efficiency in locating specific microscale regions within inhomogeneous samples. These results establish 2D-RIXS microscopy as a position-sensitive probe of elementary excitations in quantum materials and functional devices.

Journal of Synchrotron RadiationVol. 33(3)
Tohoku University (JP), National Institutes for Quantum Science and Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 23%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.