Effect of different noises on 400 × 100 Gb/s ultra-dense WDM system based on an advanced modulation technique for various channel spacings

Abstract Various types of noise can affect the signal quality and degrade the system performance while using ultra-dense wavelength division multiplexing (UD-WDM) systems. Advanced modulation techniques can help to mitigate the effects of signal distortion caused by various noises, improving signal quality and boosting transmission rate. In this paper, we have designed a 400-channel UD-WDM system with a bit rate of 100 Gb/s per channel based on a spectral efficient advanced modulation technique named 8DPSK_2ASK. The performance of the 8DPSK_2ASK modulated UD-WDM system was analyzed at channel spacings of 12.5 GHz, 25 GHz, 37.5 GHz, and 50 GHz to investigate the impact of different noise types, including dark current noise, amplified spontaneous emission (ASE) noise, and thermal noise. Performance parameters, including bit error rate (BER), quality factor (Q-factor), eye closure, received crosstalk, and received output power, have been evaluated for all the aforementioned channel spacings by varying the number of channels, transmission distance, and the applied input power. Comparing the impact of thermal noise, ASE noise, and dark current noise on the performance of the 8-DPSK_2-ASK modulated UD-WDM system, the simulation results indicated that thermal noise had the least effect on system performance at a channel spacing of 50 GHz.

Authors

Institutions

Publication Details

Journal
Journal of Optical Communications
Published
2026-03-09
DOI
https://doi.org/10.1515/joc-2026-0025
Primary Topic
Optical Network Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of different noises on 400 × 100 Gb/s ultra-dense WDM system based on an advanced modulation technique for various channel spacings

C. Nagendra Kumar, Ghanendra Kumar, Parashuram, Rajeev
Journal of Optical Communications
Optical Network Technologies
article

Effect of different noises on 400 × 100 Gb/s ultra-dense WDM system based on an advanced modulation technique for various channel spacings

C. Nagendra Kumar, Ghanendra Kumar, Parashuram, Rajeev
article en

Abstract

Abstract Various types of noise can affect the signal quality and degrade the system performance while using ultra-dense wavelength division multiplexing (UD-WDM) systems. Advanced modulation techniques can help to mitigate the effects of signal distortion caused by various noises, improving signal quality and boosting transmission rate. In this paper, we have designed a 400-channel UD-WDM system with a bit rate of 100 Gb/s per channel based on a spectral efficient advanced modulation technique named 8DPSK_2ASK. The performance of the 8DPSK_2ASK modulated UD-WDM system was analyzed at channel spacings of 12.5 GHz, 25 GHz, 37.5 GHz, and 50 GHz to investigate the impact of different noise types, including dark current noise, amplified spontaneous emission (ASE) noise, and thermal noise. Performance parameters, including bit error rate (BER), quality factor (Q-factor), eye closure, received crosstalk, and received output power, have been evaluated for all the aforementioned channel spacings by varying the number of channels, transmission distance, and the applied input power. Comparing the impact of thermal noise, ASE noise, and dark current noise on the performance of the 8-DPSK_2-ASK modulated UD-WDM system, the simulation results indicated that thermal noise had the least effect on system performance at a channel spacing of 50 GHz.

Journal of Optical Communications
Guru Gobind Singh Indraprastha University (IN), Bharati Vidyapeeth (Deemed to be University) (IN)
Affordable and clean energy
Openalex Percentile: Top 29%
Optical Network Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of different noises on 400 × 100 Gb/s ultra-dense WDM system based on an advanced modulation technique for various channel spacings — C. Nagendra Kumar, Ghanendra Kumar, et al. · Journal of Optical Communications (2026) | TGRS Research Map | TGRS