Experimental and Numerical Behaviour of Corrugated Steel-Reinforced Concrete Cross-Sections

A novel corrugated steel-reinforced concrete pipe that enhances electromagnetic shielding performance compared to the conventional reinforced concrete power pipes is developed and presented in this paper. In order to investigate the pipe’s behaviour under jacking and service conditions, the critical axial compression and flexural moment distributions were represented by two separate flat segments of a circular pipe cross-section, respectively. A total of six column specimens were designed for axial compression testing, while another four beam specimens were prepared for four-point bending tests to examine the bending behaviour. Prior to testing, all specimens were subjected to standard curing, and the material properties of steel and concrete were determined via standard tests. The load versus deformation curves of column specimens, the moment versus deflection curves of beam specimens, and the corresponding failure modes were obtained from the tested specimens. It was revealed that the load-carrying capacities of the corrugated steel-reinforced concrete cross-sections were comparable to those of the conventional reinforced concrete counterparts. Advanced finite element (FE) models incorporating the mechanical properties of encased corrugated steel plates (CSPs) and the damage development of concrete were developed and were validated against the experimental failure modes and load-carrying capacities. Based on both experimental and numerical results, the load-carrying capacity of corrugated steel-reinforced concrete cross-sections was evaluated by referring to Chinese standard GB/T 11836 and American standard ASTM C76. The experimental and numerical finding can pave the way for further research and applications of this novel type of corrugated steel-reinforced concrete pipe.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-03-09
DOI
https://doi.org/10.3390/buildings16051093
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Numerical Behaviour of Corrugated Steel-Reinforced Concrete Cross-Sections

Zicheng Lyu, Hao Yuan, Zongsheng Xu, Yufang Lin et al.
Buildings
Structural Behavior of Reinforced Concrete
article

Experimental and Numerical Behaviour of Corrugated Steel-Reinforced Concrete Cross-Sections

Zicheng Lyu, Hao Yuan, Zongsheng Xu, Yufang Lin, Yan Feng, Xinxi Du, Yanyun Jin
article en

Abstract

A novel corrugated steel-reinforced concrete pipe that enhances electromagnetic shielding performance compared to the conventional reinforced concrete power pipes is developed and presented in this paper. In order to investigate the pipe’s behaviour under jacking and service conditions, the critical axial compression and flexural moment distributions were represented by two separate flat segments of a circular pipe cross-section, respectively. A total of six column specimens were designed for axial compression testing, while another four beam specimens were prepared for four-point bending tests to examine the bending behaviour. Prior to testing, all specimens were subjected to standard curing, and the material properties of steel and concrete were determined via standard tests. The load versus deformation curves of column specimens, the moment versus deflection curves of beam specimens, and the corresponding failure modes were obtained from the tested specimens. It was revealed that the load-carrying capacities of the corrugated steel-reinforced concrete cross-sections were comparable to those of the conventional reinforced concrete counterparts. Advanced finite element (FE) models incorporating the mechanical properties of encased corrugated steel plates (CSPs) and the damage development of concrete were developed and were validated against the experimental failure modes and load-carrying capacities. Based on both experimental and numerical results, the load-carrying capacity of corrugated steel-reinforced concrete cross-sections was evaluated by referring to Chinese standard GB/T 11836 and American standard ASTM C76. The experimental and numerical finding can pave the way for further research and applications of this novel type of corrugated steel-reinforced concrete pipe.

BuildingsVol. 16(5)
State Grid Corporation of China (China) (CN), Wuhan University (CN), Wuhan Science and Technology Bureau (CN), Wuhan Municipal Engineering Design & Research Institute (CN), Shanghai Electric (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 29%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.