Trueness of Digital Versus Conventional Impressions in Mandibulectomy Models: An In Vitro Study

Background/Objectives: This in vitro study investigated the trueness of digital impressions (DIs) obtained using an intraoral scanner (IOS) compared to conventional impressions (CIs) on resin model replicas of mandibulectomy defects. Methods: Mandibulectomy resin models from 20 patients were used, including 10 partially edentulous (PE) and 10 completely edentulous (CE) patients. All models were scanned using an industrial scanner to obtain reference datasets. For CIs, silicone impressions were made in custom trays, poured into stone models, and subsequently scanned with the industrial scanner to create the test groups (n = 10 each): CI-PE and CI-CE. For the DI, an IOS (True Definition; TD) was used to directly scan the 20 models, yielding the groups DI-PE and DI-CE (n = 10 each). All test scans were superimposed on their corresponding reference scans, and trueness was assessed by calculating the mean absolute deviations (µm). Statistical analysis was performed to compare trueness across groups. Results: The mean deviations (µm) in CI-PE, CI-CE, DI-PE, and DI-CE were 26.49 ± 6.39, 23.10 ± 8.94, 76.64 ± 31.75, and 80.93 ± 33.21, respectively. Impression technique significantly affected the trueness results, with DIs showing higher overall deviations (78.78 ± 31.69 µm) than the CIs (25.24 ± 7.67 µm). No significant difference in trueness was found between partially and completely edentulous models. Conclusions: Digital impressions of mandibulectomy models made with a TD scanner had significantly lower trueness than CIs. However, the observed deviations remained within clinically acceptable limits (around 300 µm in 99.5% of the model scans), demonstrating the feasibility of TD for scanning mandibulectomy models.

Authors

Institutions

Publication Details

Journal
Oral
Published
2026-03-09
DOI
https://doi.org/10.3390/oral6020030
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trueness of Digital Versus Conventional Impressions in Mandibulectomy Models: An In Vitro Study

Islam E. Ali, Yuka I. Sumita, Kirstin Vach, M. F. Hattori et al.
Oral
Dental materials and restorations
article

Trueness of Digital Versus Conventional Impressions in Mandibulectomy Models: An In Vitro Study

Islam E. Ali, Yuka I. Sumita, Kirstin Vach, M. F. Hattori, Ralf-Joachim Kohal, Noriyuki Wakabayashi
article en

Abstract

Background/Objectives: This in vitro study investigated the trueness of digital impressions (DIs) obtained using an intraoral scanner (IOS) compared to conventional impressions (CIs) on resin model replicas of mandibulectomy defects. Methods: Mandibulectomy resin models from 20 patients were used, including 10 partially edentulous (PE) and 10 completely edentulous (CE) patients. All models were scanned using an industrial scanner to obtain reference datasets. For CIs, silicone impressions were made in custom trays, poured into stone models, and subsequently scanned with the industrial scanner to create the test groups (n = 10 each): CI-PE and CI-CE. For the DI, an IOS (True Definition; TD) was used to directly scan the 20 models, yielding the groups DI-PE and DI-CE (n = 10 each). All test scans were superimposed on their corresponding reference scans, and trueness was assessed by calculating the mean absolute deviations (µm). Statistical analysis was performed to compare trueness across groups. Results: The mean deviations (µm) in CI-PE, CI-CE, DI-PE, and DI-CE were 26.49 ± 6.39, 23.10 ± 8.94, 76.64 ± 31.75, and 80.93 ± 33.21, respectively. Impression technique significantly affected the trueness results, with DIs showing higher overall deviations (78.78 ± 31.69 µm) than the CIs (25.24 ± 7.67 µm). No significant difference in trueness was found between partially and completely edentulous models. Conclusions: Digital impressions of mandibulectomy models made with a TD scanner had significantly lower trueness than CIs. However, the observed deviations remained within clinically acceptable limits (around 300 µm in 99.5% of the model scans), demonstrating the feasibility of TD for scanning mandibulectomy models.

OralVol. 6(2)
Tokyo Institute of Technology (JP), Tokyo Medical and Dental University (JP), Mansoura University (EG), University of Freiburg (DE), Nippon Dental University (JP), Eberswalde University for Sustainable Development (DE), The University of Tokyo (JP)
Openalex Percentile: Top 29%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.