Effects of Thyroid Size and Short-lived Radionuclides on Measurement Values in Pediatric Thyroid Screening: Simulation Studies

Following the 2011 accident at the Fukushima Daiichi Nuclear Power Plant, simplified thyroid screening was carried out in children to determine internal exposure to radioactive iodine. Because NaI(Tl) scintillation survey meters - originally designed for environmental radiation - were used, quantifying radioiodine accumulated in the thyroid involved considerable uncertainty. This study investigated factors impacting measurements, specifically thyroid size (volume) and the contribution of short-lived radionuclides other than ¹³¹I (132I, 133I, and 135I) using Monte Carlo simulations with the PHITS code. For 1-y-old children, comparison between standard and minimal thyroid volumes showed that volume differences combined with variations in soft tissue thickness could cause the thyroid equivalent dose to differ by up to 76.5%. Furthermore, considering short-lived radionuclides revealed that at a ¹³¹I thyroid-equivalent dose of 100 mSv, the actual dose could reach 131.7 mSv. Thus, a screening level was used in the simplified method to effectively detect ¹³¹I. As individual differences in thyroid volume exist even among children of the same age, contributions from radionuclides other than ¹³¹I may not be negligible, impacting screening level use. The results suggest that to assess thyroid radiation dose more accurately, it is necessary to consider both age and individual thyroid volume differences, which can cause measurement errors up to 76.5%. Regarding dose contribution from short-lived radionuclides, estimates based on relative proportions of radioactive materials adhered to evacuees' clothing at the time of the accident indicated a maximum impact of 31.7%.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-03-09
DOI
https://doi.org/10.1097/hp.0000000000002119
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Thyroid Size and Short-lived Radionuclides on Measurement Values in Pediatric Thyroid Screening: Simulation Studies

Michiaki Kai, Takahiro Kitajima, Mitsuaki Ojima, Reo Etani
Health Physics
Radioactive contamination and transfer
article

Effects of Thyroid Size and Short-lived Radionuclides on Measurement Values in Pediatric Thyroid Screening: Simulation Studies

Michiaki Kai, Takahiro Kitajima, Mitsuaki Ojima, Reo Etani
article en

Abstract

Following the 2011 accident at the Fukushima Daiichi Nuclear Power Plant, simplified thyroid screening was carried out in children to determine internal exposure to radioactive iodine. Because NaI(Tl) scintillation survey meters - originally designed for environmental radiation - were used, quantifying radioiodine accumulated in the thyroid involved considerable uncertainty. This study investigated factors impacting measurements, specifically thyroid size (volume) and the contribution of short-lived radionuclides other than ¹³¹I (132I, 133I, and 135I) using Monte Carlo simulations with the PHITS code. For 1-y-old children, comparison between standard and minimal thyroid volumes showed that volume differences combined with variations in soft tissue thickness could cause the thyroid equivalent dose to differ by up to 76.5%. Furthermore, considering short-lived radionuclides revealed that at a ¹³¹I thyroid-equivalent dose of 100 mSv, the actual dose could reach 131.7 mSv. Thus, a screening level was used in the simplified method to effectively detect ¹³¹I. As individual differences in thyroid volume exist even among children of the same age, contributions from radionuclides other than ¹³¹I may not be negligible, impacting screening level use. The results suggest that to assess thyroid radiation dose more accurately, it is necessary to consider both age and individual thyroid volume differences, which can cause measurement errors up to 76.5%. Regarding dose contribution from short-lived radionuclides, estimates based on relative proportions of radioactive materials adhered to evacuees' clothing at the time of the accident indicated a maximum impact of 31.7%.

Health Physics
Nippon Bunri University (JP), Oita University of Nursing and Health Sciences (JP)
Openalex Percentile: Top 42%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Thyroid Size and Short-lived Radionuclides on Measurement Values in Pediatric Thyroid Screening: Simulation Studies — Michiaki Kai, Takahiro Kitajima, et al. · Health Physics (2026) | TGRS Research Map | TGRS